All register plates, restrictor plates, damper etc.,
which could obstruct the flue at a future date should
be removed before connecting this appliance.
If connecting to an existing chimney with a flue
diameter of more that 8" it is recommend to line the
flue using a suitable stainless steel flue liner.
Where a masonry chimney is not available a propri-
etary type of 6"/150mm - twin wall, fully insulated
pipe may be used. The pipe must terminate at a
point not lower than the main ridge of adjacent out-
side obstructions. With such installation, access to
the chimney must be provided for cleaning purpos-
es.
A chimney / flue termination must be located to min-
imise wind effects, a basic guide is that the distance
from the termination to the roof should be at be at
least 2300mm when measured horizontally and at
least 1000mm when measured vertically, (see
Fig.1). In circumstances where there are adjoining
buildings/ structures/ roof openings there are addi-
tional requirements, please refer to building regula-
tions part J.
Fig.1
FLUE EXIT (TOP & REAR)
The stove is designed to allow the chimney to be
cleaned through the stove. If the chimney cannot be
cleaned through the stove it is necessary to provide
a soot box/ access door in the flue for cleaning. See
Fig.2 for recommended locations. Fit it to the stove
as shown in Fig.2.
The stove comes partially configured for top outlet
and requires the flue spigot (supplied in the firebox)
to be fitted to the top outlet flue connection as shown
in Fig 3 using the nuts & bolts provided.
To configure for back outlet flue connection, remove
the top plate and remove the back heat shield by lift-
ing it up to remove it from its four fixing points.
Remove the flue blanking plate from the back outlet
connection. Remove the flue spigot from the top
connection and fit it to the back outlet connection. Fit
the flue blanking plate to the top outlet connection.
Remove the cut-out on the back heat shield and refit
the heat shield. Refit the hob and fit the hob blank-