SG4 & SG6 Series Full Size Gas Convection Ovens - SERVICE PROCEDURES AND ADJUSTMENTS
8.
Set the oven to call for heat and measure the Micro Amps reading.
Micro Amp reading from the flame sensor should measure a minimum of 0.7 Micro Amps to maintain burner
ignition.
If Micro Amp reading is correct and the burner does not light and maintain flame, replace ignition module.
If Micro Amp reading is NOT correct, check wiring from flame sensor/igniter to the ignition module. If wiring
is ok, replace flame sensor/igniter.
9.
Install ignition control module mounting bracket and right panel.
10. Verify operation.