Download Print this page

Salus AS20WRF Installer's/User's Manual

4 in 1 digital thermostat rf
Hide thumbs Also See for AS20WRF:

Advertisement

Quick Links

4 in 1 Digital Thermostat RF
Models: AS20WRF and AS20BRF
I N S T A L L E R / U S E R M A N U A L
SALUS North America
850 Main Street
Redwood City
CA 94063
T: +1-650-360-1725
E: sales@salusna.com
www.salusna.com
SALUS North America is a member of the Computime Group
Maintaining a policy of continuous product development, SALUS Controls plc
reserves the right to change specification, design and materials of products listed in
this brochure without prior notice.
For the latest PFD Instruction Manual, go to www.salusna.com
Product Compliance
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect
the
equipment
into
an
outlet
on
a
circuit
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
This device complies with Industry Canada's licence-exempt RSSs. Operation is subject to the
following two conditions:
(1)
This device may not cause interference; and
(2)
This
device
must
accept
any
interference,
including
interference
may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts
de licence. L' e xploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas
produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d' e n compromettre le fonctionnement.
Safety Information
Use in accordance with the regulations. Indoor use only. Keep your device completely dry.
Disconnect your device before cleaning it with a dry cloth.
Always isolate the AC Mains supply before installing or working on any components that require
120 VAC 60Hz supply.
Introduction
Thank you for purchasing the 4 in 1 room thermostat. It must be used with the Universal Gateway
JG Boiler Receiver Reduced.qxp_Layout 1 24/11/2014 10:17 Page 4
SG888ZBWH (purchased separately) when having an Internet connection or with the AKL08RF for
the underfloor system withoul Internet connection. The Universal Gateway allows communication
with other devices in the Wyse.ly system range. Other Zigbee devices include wiring
JG Boiler Receiver Reduced.qxp_Layout 1 24/11/2014 10:17 Page 4
centre, system receiver & ARV. You can download your SALUS Wyse.ly system App from the
Google Play and App Store.
Installation – AS20
Mount the back case of the thermostat on the wall. After that please insert the batteries and add
the front case. Make sure to sure to use 4AAA Alkaline batteries.
Installation – Receiver AX10RF (optional)
Note: Please install the AX10RF Receiver for your radiator system. This will ensure the
communication between the thermostat and the boiler, giving you the possibility to
switch the boiler on and off. The AX10RF receiver is optional and needs to be purchased
separately.
H
*Configured as RX1(boiler receiver)
*Configured as RX1 (stand alone receiver)
Installation – First Power Up
The following screens show examples only
MCU software
* Please note that 88.8 and 8.8 are
version will
a reference to the software version.
be shown
Please make sure that your Universal Gateway is installed. You can use it with both internet
and non internet connection. The LED will be blue when connected to the internet and red
when it's not connected.
With Internet
different
from
Without Internet
that
If you are installing an underfloor system without an Internet connection, you can use the
coordinator from the AKL08RF instead of the Universal Gateway.
Installation – Power Up your devices
Please follow the installation procedure for all equipment. After installation, your devices should
look like this:
Pairing for radiator system with Internet connection
1
4
6
8
Wait until the LED is
solid red. Press the Open/
Close button once. When
ZIGBEE software
the initialization process is
version will
complete, the LED
be shown
will go off.
Press and hold the
for 10 seconds until the ARV
starts flashing red
10
12
14
Please follow the on screen instruction in order to complete the pairing process.
Pairing for underfloor with Internet connection
1
2
3
5
4
Tap Scan for equipment when
you want to start adding
equipment to the App. The
gateway will start flashing red.
7
6
9
8
10
.
11
On step 6 please select your zone number by using the UP or DOWN arrows.
13
12
Please follow the on screen instruction in order to complete the pairing process.
2
3
5
Tap Scan for equipment
when you want to start
adding equipment to the
App. The gateway will
start flashing red.
7
9
11

Advertisement

loading

Summary of Contents for Salus AS20WRF

  • Page 1 Wyse.ly system range. Other Zigbee devices include wiring JG Boiler Receiver Reduced.qxp_Layout 1 24/11/2014 10:17 Page 4 Models: AS20WRF and AS20BRF centre, system receiver & ARV. You can download your SALUS Wyse.ly system App from the Google Play and App Store. Installation – AS20 Mount the back case of the thermostat on the wall.
  • Page 2 Pairing for radiator system without Internet connection Setting the time (for systems without internet only) Pairing for underfloor system without Internet connection 5 sec 5 sec Tap the Identify button. Your device will start flashing 3 Sec Wait until the LED is solid red.

This manual is also suitable for:

As20brf