Download Print this page

Advertisement

Quick Links

Wired Digital Thermostat
Model: AHTR5024
INSTALLER MANUAL

Advertisement

loading

Summary of Contents for Salus AHTR5024

  • Page 1 Wired Digital Thermostat Model: AHTR5024 INSTALLER MANUAL...
  • Page 2 Important info Your benefit AHTR5024 Thermostat Manual Contents: Box Contents Introduction Wired Digital Thermostat Model: AHTR5024 Product Compliance and Safety Information Installation User Interface INSTALLER MANUAL Status/LED indication Installers notes Fixing Screws 1 x Installer Manual Warranty AHTR5024 Instruction Manual...
  • Page 3 • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. AHTR5024 Instruction Manual...
  • Page 4 (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. AHTR5024 Instruction Manual...
  • Page 5: Safety Information

    This accessory must be fitted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the city, country or state where the product is installed. Failure to comply with the relevant standards could lead to prosecution. AHTR5024 Instruction Manual...
  • Page 6 The AHTR5024 device from SALUS North America is a stylish and accurate digital room thermostat that is fitted with a large easy to read LCD screen and one touch buttons.
  • Page 7 1. Mounting the Thermostat Gently remove front housing. Without floor sensor With floor sensor AHTR5024 Instruction Manual...
  • Page 8 2. Terminal Connection Note: You can wire the thermostat directly to the AKL08 wiring centre or to an actuator (purchased separatly). OPTIONAL EXTERNAL PROBE ACTUATOR OUTPUT E.G. TO MULTIPLE HEAT DEVICES PUMP OUTPUT 24VAC 230VAC 50Hz 50Hz AHTR5024 Instruction Manual...
  • Page 9 Indicates AUTO ON or AUTO OFF Indicates that the Party Mode is active Indicates that the Holiday Mode is ON. Frost Protection Indicator: Frost protection is active, not available in cooling mode. Heat Mode indicator: Indicates heating is running AHTR5024 Instruction Manual...
  • Page 10 Temperature indicator • Display the room temperature • Display the set temp Temporary override indicator: The hand will appear until the next programs starting time. Programs number indicator. Indicates the time. Indicates the the day of the week AHTR5024 Instruction Manual...
  • Page 11 Long press to return home without saving. OK key. Short press to confirm selection. Long press to save and return home. Long press to enter Temperature offset Heat/Cool. Decrease or increase Setpoint Temperature. Note: LCD backlight is activated by pressing any key. AHTR5024 Instruction Manual...
  • Page 12 When you first power up your device you 6. Setting Date and Time will have to set up the date and time. Press Press confirm. choose 12/24 hr then press to confirm. AHTR5024 Instruction Manual...
  • Page 13 Set the hour Set the minutes by using by using Press confirm. Set the date using the . Press to confirm. Note: You can access the date and hour by long pressing . After that press to confirm. AHTR5024 Instruction Manual...
  • Page 14 Press to confirm. setting the minutes. Note: If you want to select another Program Profile (from the available 5), please enter in Installer Mode, choose option d17 and after that select the desired program. AHTR5024 Instruction Manual...
  • Page 15 6:00 Sunny Sunny 7:00 Sunny Sunny 9:00 Moon Moon 23:00 Moon Moon 16:00 Sunny Sunny --:-- --:-- --:-- 23:00 Moon Moon --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- AHTR5024 Instruction Manual...
  • Page 16 6:00 Sunny Sunny 7:00 Sunny Sunny 22:30 Moon Moon 23:00 Moon Moon --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- AHTR5024 Instruction Manual...
  • Page 17 5:00 Sunny Sunny 7:30 Sunny Sunny 8:00 Moon Moon 22:30 Moon Moon 14:00 Sunny Sunny --:-- --:-- --:-- 22:00 Moon Moon --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- AHTR5024 Instruction Manual...
  • Page 18 6:00 Sunny Sunny 7:30 Sunny Sunny 9:00 Moon Moon 23:00 Moon Moon 15:00 Sunny Sunny --:-- --:-- --:-- 22:30 Moon Moon --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- AHTR5024 Instruction Manual...
  • Page 19 6:00 Sunny Sunny 7:30 Sunny Sunny 10:00 Moon Moon 23:30 Moon Moon 16:00 Sunny Sunny --:-- --:-- --:-- 23:00 Moon Moon --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- --:-- AHTR5024 Instruction Manual...
  • Page 20 8. How to reset the thermostat Press the indicated keys Select P47 if you want to Press to confirm. together for 3 seconds. reset to factory settings. Press to confirm. AHTR5024 Instruction Manual...
  • Page 21 Installer Mode. to confirm. Select your option by using Press to confirm. Note: This function allows you to customise your thermostat as you desire. In order to do this please consult the tables on the next pages. AHTR5024 Instruction Manual...
  • Page 22 F: if d03 = 1, IN disabled and OUT controls Tr Floor Protection ON-OFF: 0.5ºC (± 0.25ºC) Cooling Control ON-OFF: 1.0ºC (± 0.5ºC) Valve Protection 0 = VP disabled 1 = Enable Frost Setpoint 5ºC - 17ºC 5.0ºC AHTR5024 Instruction Manual...
  • Page 23 Turn on relay output when floor sensing temp < 10ºC 6ºC - 40ºC protecting limit, step is 0.5ºC (heating low limit-LL) Floor sensor protection limit Turn off relay output when floor sensing temp < 6ºC 6ºC - 45ºC (cooling) protecting limit, step is 0.5ºC AHTR5024 Instruction Manual...
  • Page 24 LCD screen. Ice flake will also be turned off. Note: d19 will be available only if d18 is set on 1 (Heat/Cool Mode selection Connected). AHTR5024 Instruction Manual...
  • Page 25 If you want to exit Party Mode, press time allowed on to move the (box) to a different program. the Party Mode Once Party Mode ends the countdown is 9 h 50 min and automatically resets to 0. can be set from 0-10 min. AHTR5024 Instruction Manual...
  • Page 26 Note: Vacation Modes ends when it reaches day 0. After that the device goes back to Auto Mode. 14. Frost Mode Press if you want to Press change the Frost to select Frost Mode temp. Press Mode. Press to confirm. to confirm. AHTR5024 Instruction Manual...
  • Page 27 Long press in order Press to enter Press in order to to enter Settings Mode. Setting Mode. set the Temperature Offset. The Temperature Offset can be set at any value between -3ºC and +3ºC. Press to confirm. AHTR5024 Instruction Manual...
  • Page 28 125 g net / 170 g gross Puls-wide-modulation (PWM) Yes Clock, Timer Yes, programmable Profile Modes 3 ( Sun, Moon, Automatic) Heating and Cooling Yes, automatically Change Over on the Wiring Centre Parameter adjustment Yes, in Installer Mode Dimensions 85mm*85mm*25mm AHTR5024 Instruction Manual...
  • Page 29 Notes ..............................................................................................................................................................................................................................................................................................................................................................................................................................................AHTR5024 Instruction Manual...
  • Page 30 Notes ..............................................................................................................................................................................................................................................................................................................................................................................................................................................AHTR5024 Instruction Manual...
  • Page 31 SALUS North America sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
  • Page 32 SALUS North America is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification, design and materials of products listed in this brochure without prior notice. For PDF Installation guide please go to www.salusna.com...