Monitoring The V6100 Trunks And B-Channels - 3Com v6100 Installation Manual

Hide thumbs Also See for v6100:
Table of Contents

Advertisement

Table 4
Functionality of the Front Panel LEDs
LED
Location
RJ-48c
1
Ethernet
2
Ports I & II
General
3
Purpose
Power
4
Supply

Monitoring the V6100 Trunks and B-channels

To monitor the status of the trunks and B-channels:
Open the 'Trunk & Channel Status' screen (Status & Diagnostics menu > Channel
Status); the 'Trunk & Channel Status' screen is displayed.
Figure 13
Trunk & Channel Status Screen
36
Color
State
LED Indication
Green
On
Trunk is synchronized (normal operation)
Loss due to any of the following 4 signals:
LOS
LOF
Red
On
AIS
RAI
Green
On
Link OK.
Yellow
Blinking
Data is being received.
Green
On
Normal working condition.
Green
Blinking
Software load / initialization.
Red
On
Failure. A fatal error has occurred.
The LED of each AC power supply is lit green when the
Green
On
power supply is operating correctly.
Either there is a failure / disruption in the AC power
-
Off
supply or the power is currently not being supplied to the
V6100 through the AC power supply entry.
Loss of Signal
Loss of Frame
Alarm Indication Signal (the Blue Alarm)
Remote Alarm Indication (the Yellow Alarm)
This general purpose
LED is used to
indicate the status of
the CPU, fans, etc.
V6100 Digital Gateway Installation Guide