Cisco IR829 Hardware Installation Manual page 16

Industrial integrated services router
Hide thumbs Also See for IR829:
Table of Contents

Advertisement

LEDs
Table 1: LED Descriptions
LED
PWR
POE
VPN
Cisco IR829 Industrial Integrated Services Router Hardware Installation Guide
14
Activity
Description
Power Status
In normal operating mode, after system
boots. (typically about 2 minutes)
Off — No power
Green Steady on — Router is reachable,
and all interfaces are up and functioning
properly
Green Flashing — Router is reachable, and
no interface is in a failed state
Amber Steady on — Router is unreachable
(An external interface of the router, that
prevents the router from being remotely
managed, is in a critical failed state)
Amber Flashing — Router is reachable,
but at least one of the interfaces is in a
non-critical failed state (functionality of
that interface is affected)
In bootup mode (during the first 60
seconds after powerup)
Green Steady on — Router is booting
Amber Steady on — Router has a system
hardware failure
In ROMMON mode:
Amber Steady on — Router is in bootup
phase or in ROM Monitor mode.
POE Power
Off — No -54V PoE power supply detected
Supply Status
or no PoE board installed
Green Steady on — 54V POE power
supply good and all powered port operating
normally
Amber Steady on — 54V POE power
supply good, but one or more POE ports
has a fault.
VPN
Off — No VPN tunnel
Steady on — At least one VPN tunnel is
up
Product Overview