Extended Storage Instructions (Exceeding Six Months) - Mercury TDI 3.0L Owner's Operation And Maintenance Manual

Sterndrive models
Hide thumbs Also See for TDI 3.0L:
Table of Contents

Advertisement

Description
QuickGuard Diesel Fuel Treatment
2.
Supply cooling water to the water inlet holes or seawater pump inlet.
3.
Start the engine and operate until it reaches normal operating temperature.
4.
Stop the engine.
5.
Change the engine oil and filter. Refer to Section 4 ‑ Engine Oil.
6.
Flush the seawater cooling system. Refer to Section 4 ‑ Seawater System.
7.
Check for oil leaks.
8.
Drain the seawater system and protect it with propylene glycol antifreeze. Refer to Section 4 ‑ Seawater System.
NOTE: Before starting the engine to draw in the propylene glycol antifreeze, remove the air filter. Start the engine and
spray a small amount of Storage Seal Rust Inhibitor into the intake pipe.
IMPORTANT: An excessive amount of Storage Seal is not required. The intention is to coat the compressor portion of the
turbocharger only, and not the engine combustion chambers. Never introduce an excessive amount of oil to the intake of a
diesel engine.
Tube Ref No.
Storage Seal Rust Inhibitor
119
9.
Immediately stop the engine when the propylene glycol antifreeze has been drawn into the engine.
10. Install the air filter.
11. Clean the outside of the engine and paint damaged areas with primer and spray paint. After the paint has dried, apply a
corrosion‑inhibiting spray or equivalent.
Description
Corrosion Guard
Mercury Light Gray Primer
Mercury Warm Fusion White
Mercury Phantom Black
12. Your Mercury Diesel authorized repair facility should now perform all checks, inspections, lubrications, and fluid changes
outlined in Section 4 ‑ Maintenance Schedules—Alpha and Bravo Models.

Extended Storage Instructions (Exceeding Six Months)

IMPORTANT: Mercury Marine strongly recommends that this service be performed by a Mercury Diesel authorized repair
facility.
1.
Read all precautions and perform all procedures found in Seasonal Storage Instructions (Six Months or Less).
2.
Read all precautions and perform all procedures found in Section 4 ‑ Seawater System.
3.
Treat the fuel in the fuel tank with QuickGuard Diesel Fuel Treatment per instructions on the label.
Description
QuickGuard Diesel Fuel Treatment
4.
Supply cooling water to the water inlet holes or seawater pump inlet.
90-8M0145546
MAY 2018
eng
Description
Where Used
Turbocharger inlet vanes
Where Used
Outside of engine
58414
Section 5 - Storage
Part Number
8M0089197
Part No.
92-858081K03
Part Number
92‑80287855
92‑80287852
8M0094987
92‑802878Q1
Part Number
8M0089197
Page 89

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents