Cleaning the Cleaning Pad

If the cleaning pad becomes dirty, clean it gently using a commercially available brush (item with soft fibers) or the like.
The Cleaning Pad
If the cleaning pad on the left edge of the unit's front surface is damaged, the printing head may be destroyed.
If the cleaning pad is damaged by a blade or the like, replace it with a new cleaning pad.
Continuing to use a cleaning pad that has deteriorated may impair printing quality.
As a general guideline, the cleaning pad should be replaced with a new one after printing 50 m (1960 in.) of material (24 in. in width).

Replacing the Cleaning Pad

NOTICE
When printing, be sure a cleaning pad is installed. Performing printing with no cleaning pad installed may
destroy the printing head.
Continuing to use a cleaning pad that has deteriorated may impair printing quality.
As a general guideline, the cleaning pad should be replaced with a new one after printing about 50 m of material (24" in width).
Also, if the cleaning pad becomes damaged, replace it immediately.
Failure to replace it may cause destruction of the printing head.
Follow the steps below to replace the cleaning pad.
1
Remove the old cleaning pad.
Peel off slowly from the right-hand corner.
Cleaning pad
3
Check the following:
- Make sure the cleaning pad has not come loose.
- Make sure there is no gap between the cleaning
pad and the platen stopper.

Cleaning the Reflective Panel

If the reflective panel becomes dirty, clean it by moistening a cloth with water, wringing well, and wiping gently.
2
Install the new cleaning pad.
While orienting as shown
in the figure and holding
all the way to the left,
press into place.
Chapter 3 - User's Reference
Platen stopper