Display
Displays the Display Diagnostics menu.
Backlight
Turns the backlight on and off (even if the
backlight is disabled).
Pixel
Turns all display pixels on and off.
Exit
Returns to the Main Diagnostics menu.
Keyboard
Runs the keyboard test.
Prompts the user to install the loopback plug and runs
the diagnostics. It tests all supported baud rates, and
checks the parity and control lines.
Before running this test, take the top of the printer off
and remove the +5 volt jumper. The test fails with the
jumper on.
Runs the RAM diagnostics.
Displays the application and hardware versions.
Returns to the Main Printer menu.

Online Diagnostics

Sets access to online diagnostics.
Enable
Enables access to online diagnostics.
Disable
Disables access to online diagnostics.
Exit
Returns to the Main Printer menu.
Page 16
Comm.
RAM
About
Exit
Confidential

Setup

Displays the Setup Main menu.
Sets the type of supply being used.
Standard
Standard supplies are being used.
High Energy
Synthetic or linerless supplies are being used.
Exit
Returns to the Setup Main menu.
Enables or disables the backlight.
Enable
Turns the backlight on.
Disable
Turns the backlight off.
Exit
Returns to the Setup Main menu.
Sets the contrast of the display.
Displays the Printer Setup menu.
Contrast
Adjusts the print contrast.
Supply Pos
Adjusts the supply position.
Print Pos
Adjusts the print position.
Margin Adj
Adjusts the margin position.
Demand Sensor
Enables or disables the on-demand sensor.
Stock Sensor
Changes the sensor type and automatically
enters into the calibration routine for that
sensor.
Exit
Returns to the Setup Main menu.
Diagnostics
Stock Energy
Backlight