5. Operation check procedure of automatic slide gate

In the case of the suction hopper type SD control collection hopper, manually operate the
automatic slide gate. The methods for checking the operation are described according to the
steps.
Step
○ Do not place fingers or hands into the movable parts (slide part) during operation.
Tears or bone fractures may result.
○ Never operate with the cover of the movable part removed.
○ Never operate with material caught in the slide damper. Failure may result.
[WO-4841;JL4-V・VC-3~6-48]
Turn "OFF" the control panel power circuit breaker.
Supply dry compressed air of 0.4 MPa to 0.5 MPa to the air kit of the automatic slide
gate.
Press the manual button on the solenoid valve. The air cylinder starts to operate.
Movable part
可動部
Main body of automatic slide gate
自動スライドダンパー本体
Chapter 8 Inspection and Maintenance
Details of operation
Cylinder
シリンダー
Safety cover
安全カバー
DO NOT SOIL OR PEEL THIS LABEL
このラベルをはがしたり、よごしたりしないこと。
WARNING
- 48 -
Stop valve
ストップバルブ
Filter regulator
フィルター
レギュレーター
CAUTION
注 意
WATCH YOUR FINGERS
指 づ め 注 意
1.
運転中は指や手を可動部に入
1.Do not place fingers or hands in movable
れるな。
sections during operations.
2.Take care to avoid lacerations to fingers or
2.
裂傷や骨折するおそれがあ
hands and danger of them being broken.
る。
3.When performing cleanup of or inspection
3.
清掃・点検作業は電源を OFF
turn power OFF and shut off air supply.
にしてエアー供給源を遮断して