Component Adjustment Procedure - Matsui JL4-5V-3~6 Operation Manual

Jl4 series u version jet loader
Table of Contents

Advertisement

3. Component adjustment procedure

1)
Jet Clone gate cam
Adjust the gate cam when full is not detected
regardless of whether the material is full.
Step
1
Loosen the set-screw with a hexagon rod spanner (2.5mm).
2
Adjust the gate cam position so that the limit switch is ON with the gate
lowering from the horizon by 45-50°.
3
After adjusting the cam, secure it by tightening the set-screw.
2)
Balance weight for Jet clone
In a case where material is attached to the damper
due to static electricity, the state shown on the right
is brought about in rare cases. In such a case, adjust
the damper by loosening two locking screws for
the balance weight rearward by 5mm, respectively,
so as to be horizontally positioned. Retighten screws
for fixing after adjustment.
[WO-4841;JL4-V・VC-3~6-44]
This section describes the adjustment procedure of the full detecting
device attached to each collection hopper.
Details of operation
- 44 -
Chapter 8 Inspection and Maintenance
Limit switch
Gate
Set-screw