3. Component adjustment procedure
1)
Jet Clone gate cam
Adjust the gate cam when full is not detected
regardless of whether the material is full.
Step
1
Loosen the set-screw with a hexagon rod spanner (2.5mm).
2
Adjust the gate cam position so that the limit switch is ON with the gate
lowering from the horizon by 45-50°.
3
After adjusting the cam, secure it by tightening the set-screw.
2)
Balance weight for Jet clone
In a case where material is attached to the damper
due to static electricity, the state shown on the right
is brought about in rare cases. In such a case, adjust
the damper by loosening two locking screws for
the balance weight rearward by 5mm, respectively,
so as to be horizontally positioned. Retighten screws
for fixing after adjustment.
[WO-4841;JL4-V・VC-3~6-44]
This section describes the adjustment procedure of the full detecting
device attached to each collection hopper.
Details of operation
- 44 -
Chapter 8 Inspection and Maintenance
Limit switch
Gate
Set-screw