7.1.6. Measuring the permeation rate

NOTE
The device is subject to operating pressure and energised
The device is subject to operating pressure and energised during the execution of maintenance 
works
The following prerequisites must be created for measuring the permeation rate – as a status evaluation for the membrane
itself
  P rocure a suitable volume flow measuring device in the range 10 – 100 l/minute (atmospheric) with connection 
connecting hose (approx. 1 m) / plug-in connector with connection thread G1/4
Set the DRYPOINT
M eco control to "Service Mode" operating method, Refer to 6.3.3 (the device interior will only be
®
provided with measuring gas flow)
Measuring process
Screw out the blind plugs on the membrane dryer head
Exiting purge air is reduced to depressurised
  S crew in the connector G1/4 from the hose connector volume flow of the measuring device in the thread G1/4 in the 
head
  H old close / adhere the purge air outlets
Read out the measurement results
The connection in the head of the membrane dryer must be sealed again with the blind plugs after the measuring process
and the purge air outlet on the screen must be freed again. Subsequently reset the device in normal mode (Refer to 6.3.3.)
Recommended limiting values in l/minute: approx. 25% of the maximum purge air volume for DRYPOINT
plus 5 l/minute (share of measuring gas flow).