Synchronizing a New Panel with Information on an Existing
Panel
Replace a v6.0 Primary Panel in an Existing Loop (Web
Mode)

Overview

Details the steps to replace a NetAXS-123 v6.0 "Primary" panel with existing "Secondary"
panels wired via RS-485 or Ethernet Virtual Loop (EVL). The System Wide Restore in the
Primary is required with an existing backup.
When the download is completed, the panel is immediately rebooted. A status bar
indicates the progress of the reboot.
No special operation is required. For any new secondary panel added in a loop,
Primary Panel will push card and common configuration to the new panel so basic
databases will already be synced up once panel is detected/added.
Note
Synchronization will occur when adding a new panel in a loop or after
upgrade from Rev 5 or lower firmware.
The secondary panel will reboot after the panel is synchronized.
Primary panel to the Secondary panel synchronization occurs at the time the
Secondary panels are "Registered" with the Primary and will include the
common data.