Air-Fi® Wireless Communications System - Trane UniTrane Installation, Operation And Maintenance Manual

200-1200 cfm fan coil, cabinet heater, low vertical models
Table of Contents

Advertisement

Air-Fi® Wireless Communications
System
For more detailed information on Air-Fi® Wireless
Communications system and devices, see:
BAS-SVX40*: Air-Fi® Wireless Installation, Operation,
and Maintenance
BAS-PRD021*-EN: Air-Fi® Wireless Product Data
Sheet
BAS-SVX55*: Air-Fi® Wireless Network Design
Air-Fi® Wireless Communications
Interface (WCI)
A factory-installed Air-Fi® Wireless Communications
Interface (WCI) provides wireless communication
between the Tracer® SC and Tracer® unit controllers. The
Air-Fi® WCI is the perfect alternative to a Trane BACnet®
wired communication link. Eliminating the
communication wire between terminal products, space
sensors, and system controllers has substantial benefits:
Reduced installation time and associated risks.
Completion of projects with fewer disruptions.
Easier and more cost-effective re-configurations,
expansions, and upgrades
Air-Fi® Wireless Communications Sensor
(WCS)
Communicates wirelessly to a Tracer® unit controller. A
WCS is an alternative to a wired sensor when access and
UNT-SVX07J-EN
routing of communication cable are issues. A WCS allows
flexible mounting and relocation.
Wireless Zone Sensor (WZS) Set
A wireless zone sensor (WZS) set (sensor and receiver)
communicates wirelessly to a Tracer® unit controller. A
wireless zone sensor set is an alternative to a wired sensor
when access and routing of communication cable are
issues. The sensor allows flexible mounting and
relocation.
Note: A wireless zone sensor set is not compatible with
an Air-Fi® wireless system.
The Wireless Comm Interface (WCI) enables wireless
communication between system controls, unit controls,
and wireless sensors for the new generation of Trane
control products.The WCI replaces the need for
communication wire in all system applications.
Note: For more detailed information, refer to:
BAS-SVX40A-EN - Wireless Comm Installation,
Operation and Maintenance manual
BAS-SVX55A-EN - Wireless Comm Network Design
Best Practices Guide
Quantity of WCIs per Network
Each Trane wireless network can have a total of 31 WCIs
(30 member WCIs plus one coordinator WCI). Each
network requires one WCI to function as network
coordinator.
Quantity of Networks per Tracer® SC
A Tracer® SC can support up to eight wireless networks.
Automatic Network Formation
When a WCI is connected to a Tracer® SC, it is auto-
assigned as the coordinator.To enable the coordinator,
Tracer® SC must be configured for wireless
communication.The coordinator WCI opens the network
to allow all WCIs having matching addresses to
automatically join the network. If no Tracer® SC is present,
a centrally located WCI must be designated to act as the
coordinator.You can manually set the coordinator WCI so
Installation - Controllers
89

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Force-floFcFfFckbFclb

Table of Contents