Model Number Descriptions; Unitrane™ Fan Coil/Force Flo™ Cabinet Heater - Trane UniTrane Installation, Operation And Maintenance Manual

200-1200 cfm fan coil, cabinet heater, low vertical models
Table of Contents

Advertisement

Model Number Descriptions

UniTrane™ Fan Coil/
Force Flo™ Cabinet
Heater
Following is a complete description of
the UniTrane fan coil and Force Flo
cabinet heater model number. Each digit
in the model number has a
corresponding code that identifies
specific unit options.
Note: Not all options are available on all
cabinet styles. Contact your local
Trane sales representative for
more information.
Digits 1, 2 — Unit Type
FC =
Fan Coil
FF =
Force Flo
Digit 3 — Model
A
=
Vertical concealed
B
=
Vertical cabinet
C
=
Horizontal concealed
D
=
Horizontal cabinet
E
=
Horizontal recessed
F
=
Vertical Wall-hung
H
=
Vertical recessed
J
=
Vertical slope-top
M =
Inverted vertical cabinet
N
=
Inverted vertical recessed
P
=
Compact concealed
Digit 4 — Development
Sequence
B
=
Development B
Digits 5, 6, 7 — Unit Cabinet
Size
020 =
200 cfm
030 =
300 cfm
040 =
400 cfm
060 =
600 cfm
080 =
800 cfm
100 =
1000 cfm
120 =
1200 cfm
Digit 8 — Unit Voltage
1
=
115 V/60 Hz/1 PH
2
=
208 V/60 Hz/1 PH
3
=
277 V/60 Hz/1 PH
4
=
230 V/60 Hz/1 PH
5
=
208 V/60 Hz/3 PH
6
=
230 V/60 Hz/3 PH
7
=
480 V/60 Hz/3 PH
8
=
115 V/50 Hz/1 PH (SOS ONLY)
9
=
220-240 V/50 Hz/1 PH
A
=
220-240 V/50 Hz/3 PH
B
=
380-415 V/50 Hz/3 PH
Digit 9 — Piping System /
Placement
A
=
Without pipe, RH, Without
auxiliary
B
=
Without pipe, LH, Without
auxiliary
C
=
Without pipe, RH, With auxiliary
D
=
Without pipe, LH, With auxiliary
UNT-SVX07J-EN
E
=
Without pipe, RH, Without
auxiliary, Extended end
F
=
Without pipe, LH, Without
auxiliary, Extended end
G
=
Without pipe, RH, With auxiliary,
Extended end
H
=
Without pipe, LH, With auxiliary,
Extended end
J
=
With pipe, RH
K
=
With pipe, LH
L
=
With pipe, RH, Extended end
M =
With pipe, LH, Extended end
N
=
Without pipe, RH, With auxiliary,
Extended end pipe and control
side
P
=
Without pipe, LH, With auxiliary,
Extended end pipe and control
side
Q
=
With pipe, RH, With auxiliary,
Extended end pipe and control
side
R
=
With pipe, LH, With auxiliary,
Extended end pipe and control
side
Digits 10, 11 — Design
Sequence
*** =
Factory assigned
AW =
AW design
Digit 12 — Inlet Style
A
=
Front toe space
B
=
Front bar grille
C
=
Front stamped louver
D
=
Bottom stamped louver
E
=
Bottom toe space
F
=
Back duct collar
G
=
Back exposed fan
H
=
Back stamped louver
J
=
Top duct collar
K
=
Exposed fan
L
=
Bottom filter
Digit 13 — Outside Air Damper
0
=
None
A
=
Manual, Bottom opening
B
=
Manual, Back opening
C
=
Manual, Top opening
D
=
Auto, 2-position, Bottom
opening
E
=
Auto, 2-position, Back opening
F
=
Auto, 2-position, Top opening
G
=
Economizer, Bottom
opening
H
=
Economizer, Back opening
J
=
Auto, Economizer, Top opening
K
=
No damp, Bottom opening
L
=
No damp, Back opening
M =
No damp, Top opening
Digit 14 — Outlets Style
A
=
Front duct collar
B
=
Front bar grille
C
=
Front stamped louver
D
=
Front quad grille
E
=
Bottom duct collar
F
=
Bottom stamped louver
G
=
Top quad grille
H
=
Top bar grille
J
=
Top duct collar
K
=
Bottom bar grille
Digit 15 — Paint Cabinet Color
0
=
None (Not painted unit)
1
=
Deluxe beige
2
=
Soft dove
3
=
Cameo white
4
=
Driftwood grey
5
=
Stone grey
6
=
Rose mauve
Digit 16 — Tamperproof Locks /
Leveling Feet
0
=
None
A
=
Locking panel
B
=
Keylock access door
C
=
Locking panel, Keylock access
door, Secure grille
D
=
Leveling feet
E
=
Locking panel with
leveling feet
F
=
Keylock door with
level feet
G
=
Locking panel, Key access door,
Secure grille, Leveling feet
Digit 17 — Motor Types
A
=
Free discharge
B
=
High static
Digit 18 — Main Coil
A
=
2-row cooling/heating
B
=
3-row cooling/heating
C
=
4-row cooling/heating
D
=
2-row cooling, 1-row heating
E
=
2-row cooling, 2-row heating
F
=
3-row cooling, 1-row heating
G
=
2-row cooling only or heating
only
H
=
3-row cooling only or heating
only
J
=
4-row cooling only or heating
only
K
=
2-row cooling/heating, Electric
heat
L
=
3-row cooling/heating, Electric
heat
M =
4-row cooling/heating, Electric
heat
N
=
Electric heat only, 1 stage
P
=
2-row cooling/heating, 1-row
heating
Q
=
2-row cooling/heating, 2-row
heating
R
=
3-row cooling/heating, 1-row
heating
U
=
Electric heat only, 2 stage
V
=
Electric heat, Low kW, 1 stage
W =
Steam coil
X
=
2-row cooling only, Electric
heat
Y
=
3-row cooling only, Electric
heat
Z
=
4-row cooling only, Electric
heat
1
=
3-row cooling, 1-row heating
with high capacity
2
=
3-row cooling/
heating, 1-row heating with high
capacity
3
=
Heat pump
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Force-floFcFfFckbFclb