Condensate Drain Lines & Drain Trap; Concentric Vent Termination; Side Wall Vent Kit; General Drain Information - Goodman MEC961205DN Instruction Manual

*mec96 & *cec96 series two-stage gas furnaces
Table of Contents

Advertisement

C
V
T
ONCENTRIC
ENT
ERMINATION
Refer to the directions provided with the Concentric Vent Kit
(CVENT) for installation specifications.
S
W
V
K
IDE
ALL
ENT
IT
This kit is to be used with 2" or 3" direct vent systems. The
vent kit must terminate outside the structure and may be in-
stalled with the intake and exhaust pipes located side-by-side or
with one pipe above the other. These kits are NOT intended for
use with single pipe (non-direct vent) installations.
Refer to the directions furnished with the Side Wall Vent Kit
(p/n 0170K00000S or 0170K00001S) for installation speci-
fications.
H oriz ontal Installation
Ve rtica l Ins tallation

Side Wall Vent Kit

C
D
L
ONDENSATE
RAIN
INES
A condensing gas furnace achieves its high level of efficiency by
extracting heat from the products of combustion to the point
where condensation takes place. The condensate must be col-
lected in the furnace drain trap and routed to an appropriate
drain location in compliance with local and national codes.
Follow the bullets listed below when installing the drain sys-
tem. Refer to the following sections for specific details con-
cerning furnace drain trap installation and drain hose hook
ups.
The drain trap supplied with the furnace must be
used.
The drain trap must be primed at time of
installation.
The drain line between furnace and drain location
must meet local and national codes.
The drain line between furnace and drain location
must maintain a 1/4 inch per foot downward slope
toward the drain.
Do not trap the drain line in any other location
than at the drain trap supplied with the furnace.
If the drain line is routed through an area which
may see temperatures near or below freezing,
precautions must be taken to prevent condensate
from freezing within the drain line.
Figure 19
& D
T
RAIN
RAP
If an air conditioning coil is installed with the
furnace, a common drain may be used. An open
tee must be installed in the drain line, to relieve
positive air pressure from the coil's plenum. This
is necessary to prohibit any interference with the
function of the furnace's drain trap.
G
D
I
ENERAL
RAIN
NFORMATION
All furnace models come with a factory installed drain trap.
For vertical installations, the trap will remain in the factory
position. All furnace models installed horizontally require
the trap to be relocated. Many drain hoses have a built–in
grommet which will provide a cabinet seal when installed.
See instructions below for your model and installation posi-
tion. NOTE: Both sides of the drain trap must be primed
prior to initial furnace start up
F
S
D
IELD
UPPLIED
RAIN
Drain the furnace and air conditioning coil if applicable, in
compliance with code requirements. In horizontal installa-
tions, a field installed rubber coupling will allow the drain
trap to be removed for cleaning. The drain trap must be
primed before initial furnace start up. When an air condi-
tioning coil drain is connected to the field supplied furnace
drain, it must be vented with an open tee installed at a height
no higher than the bottom of the furnace collector box to
prevent air conditioning condensate from backing up into
the furnace if the common drain became blocked.
18