Download Print this page
Goodman *MEC96 Technical Manual

Goodman *MEC96 Technical Manual

34.5" 2-stage multi-speed ecm gas furnace
Hide thumbs Also See for *MEC96:

Advertisement

Quick Links

TECHNICAL MANU
TECHNICAL MANU AL
TECHNICAL MANU
TECHNICAL MANU
TECHNICAL MANU
MULTI-SPEED ECM GAS FURNACE
Refer to Service Manual RS6612013 for installation, operation, and troubleshooting information.
All safety information must be followed as provided in the Service Manual.
Refer to the appropriate Parts Catalog for part number information.
Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does
not assume any responsibility for property damage or personal injury due to improper service
procedures performed by an unqualified person.
*MEC96
34.5" 2-STAGE
96% AFUE
UP TO
® Copyright 2014 Goodman Company, L.P.
is a registed trademark of Maytag Corporation or its related companies and is used under license to
®
Goodman Company, L.P., Houston, TX, USA. All rights reserved.
AL
AL
AL
AL
RT6612030r1
August 2014

Advertisement

loading

Summary of Contents for Goodman *MEC96

  • Page 1 Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3. This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does RT6612030r1 not assume any responsibility for property damage or personal injury due to improper service August 2014 procedures performed by an unqualified person.
  • Page 2: Product Identification

    Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Goodman will not be responsible Installation and repair of this unit WARNING WARNING...
  • Page 3 WARNING that is not design certified by damage, personal injury, or death, Goodman for use with this unit. do not store combustible materials or use gasoline or Serious property damage, personal injury, reduced unit other flammable liquids or vapors in the vicinity of this performance and/or hazardous conditions may result appliance.
  • Page 4: Product Dimensions

    *MEC96 PRODUCT DIMENSIONS DISCHARGE DISCHARGE DIM B 6‰ DISCHARGE 6‰ AIR INTAKE 2" PIPE 19‰ CENTER DIMPLE VENT/FLUE PIPE LEFT SIDE FOR ALTERNATE ALTERNATE 2" PVC DRAIN TRAP AIR INTAKE PIPE VENT/FLUE EXTERIOR HOLES 3" OD HOLE LOCATION HIGH VOLTAGE RIGHT SIDE ELECTRICAL OUTLET DRAIN TRAP...
  • Page 5: Furnace Specifications

    *MEC96 FURNACE SPECIFICATIONS *MEC96 *MEC96 *MEC96 *MEC96 *MEC96 *MEC96 0302BNA 0402BNA 0603BNA 0803BNA 1004CNA 1205DNA Heating Data High Fi re Input¹ 30,000 40,000 60,000 80,000 100,000 120,000 High Fi re Output¹ 28,800 38,400 57,600 76,800 96,000 115,200 Low-Fi re Steady-Sta te Input¹ 21,000 28,000 42,000...
  • Page 6 *MEC96 AIRFLOW DIP SWITCH SETTING *MEC960302BN CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM All DIP Sw itch Positions All DIP Sw itch Positions FACTORY All DIP Sw itch Positions SETTING OFF OFF OFF 1146 1097 1049 1002...
  • Page 7 *MEC96 AIRFLOW DIP SWITCH SETTING *MEC960603BN CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM All DIP Switch Positions All DIP Switch Positions FACTORY All DIP Switch Positions 1328 1287 1249 1215 1170 1131 1085 1046 SETTING OFF OFF OFF 1236...
  • Page 8 *MEC96 AIRFLOW DIP SWITCH SETTING *MEC961004CN CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM 1522 1464 1402 1338 1280 1230 1167 1101 All DIP Sw itch Positions 1522 1464 1402 1338 1280 1230 1167 1101 All DIP Sw itch Positions FACTORY All DIP Sw itch Positions...
  • Page 9: Wiring Diagrams

    *MEC96 WIRING DIAGRAMS WARNING:DISCONNECT POWER BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. TO 115VAC/ 1 /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE WARNING: DISCONNECT POWER BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED.