Analog Line Interface (Fxs) - Mitel TA7102 Installation Manual

Hide thumbs Also See for TA7102:
Table of Contents

Advertisement

Protocols
Fax Data Compression
Fax Transmission
7.5

ANALOG LINE INTERFACE (FXS)

RJ-11 connectors
Direct connection to a fax machine or telephone (Internal installation and internal cabling)
DC feeding of the access line protected for over voltage
Loop current detection and hook flash detection capable
Generation of Selective Ring
Table 15: Analog Line Interface
Parameter
Trunk Type
Ring Source
Nominal Impedance
Ring Drive Capacity
Loop Current Range
Ring Trip Detection Time
On Hook Voltage
Frequency Response
Return Loss
153/1531-ANF 901 14 B 2017-03-08
Group 3 Fax
Clear channel (G.711), G.726 or T.38 Real Time Fax Over IP
protocol
Stack
MH
Up to 14.4 kbps
Description
Loop Start: capable of Wink and Immediate signalization
50 VRMS max @ 20 up to 50 Hz (selectable) sine signal
BellCore compliant 600/900 ohms default setting.
Up to 4 ringer equivalents (4 RENs) per port.
15 to 32 ma factory set. Default 20 ma regulated.
2 ring cycles max
-48 VDC
200 Hz to 3400 Hz ±3 dB (Tx/Rx)
500-3200 Hz: 30 dB
TA7102 Hardware Installation
45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents