Receiving A Control Map From Your Computer (Bulk Receive) - Roland Edirol PCR-300 Owner's Manual

Midi keyboard controller
Hide thumbs Also See for Edirol PCR-300:
Table of Contents

Advertisement

Using control maps

Receiving a control map from your computer (Bulk Receive)

The PCR-300/500/800 can receive control map data in the form of a bulk dump.
If you want control map data you've created using PCR Editor to be received into the
PCR's current memory, you'll need to make settings in PCR Editor so that the PCR will
be ready to receive a bulk dump. If you want the PCR to receive this data as messages
from your DAW software, you'll need to make settings on the PCR keyboard so that it
will be ready to receive a bulk dump.
Here we'll explain how to make settings on the PCR keyboard so that it will be able
to receive a bulk dump.
For more about PCR Editor, refer to Using PCR Editor (p. 14). For details on how
to receive a control map from PCR Editor, refer to Transferring data between PCR
Editor and the PCR (p. 22).
fig.H-Edit.eps
1
Press the [EDIT] button so it's lit.
fig.D-Edit.eps
The display will indicate "EDIT."
fig.D-Bulk.eps
2
Turn the VALUE knob to make the display indicate "BULK."
fig.D-BulkR.eps
3
Press the [ENTER] button.
"BLR" will blink in the display (Bulk Receive).
10
4
Verify that the display indicates "BLR" (Bulk Receive), and then press the [ENTER]
button.
If the display indicates "BLT" (Bulk Transmit), use the VALUE knob to make it
indicate "BLR" (Bulk Receive).
5
Use the VALUE knob or the controllers to choose the reception method. Choose
the method that's appropriate for the data you'll be receiving.
Controller
Item
Display
SINGLE
[A1 (0)]
BULK
[A2 (1)]
ALL BULK
fig.D-RSBulk-Wait.eps
6
Verify that the display indicates the correct choice, and press the
[ENTER] button. The rightmost digit of the display will blink, and
the PCR will wait for bulk data to arrive.
About the display in Bulk mode
Receive/Transmit
Receive
Transmit
SINGLE BULK / ALL BULK
SINGLE
ALL
BULK
BULK
Transmitting/Receiving/Waiting
Receive
Transmit
Waiting
Waiting
(blinking)
(blinking)
Explanation
One control map will be received.
The received data will overwrite the
current memory.
Memories 1–F will not be affected.
Data for all fifteen control maps will
be received. The received data will
overwrite internal memories 1–F.
Receiving
Transmitting

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Edirol pcr-500Edirol pcr-800

Table of Contents