Specifications - Mira Elite QT Installation & User Manual

9.8kw / 10.8kw
Table of Contents

Advertisement

Specifications

Plumbing
Maximum Static Pressure
Minimum Static Pressure
Minimum Inlet Temperature
Maximum Inlet Temperature
Maximum Water Hardness
Inlet
Outlet
Electrical
Power Supply
Duty Cycle
Maximum Supply Cable Size
Recommended RCD Rating
Recommended Isolator Switch
Recommended MCB Rating
Ingress Protection Rating
Minimum Ambient Temperature
Maximum Ambient Temperature
Dimensions (shower unit)
Height
Width
Depth
The Mira Elite QT complies with the following European directives:
2006/95/EC Low Voltage Directive, 2004/108/EC EMC Directive, 2011/65/EU RoHS Directive.
The Mira Elite QT is a high power appliance and is subject to conditional connection. If the
main electrical supply fuse is rated less than 80 Amps, the local electricity supply company
must be contacted to confirm if the electrical supply is adequate.
The Mira Elite QT complies with the requirements of the UK's water regulations.
Design Registration & Patents
Patents: GB 2 289 323, 2 341 667, 2 359 339, 2 427 460, 2 432 201
Ireland: 80655, 82835, 83692
1265606-W2-A
100 kPa (1 bar)
0.8 kPa (0.008 bar)
2°C
30°C
200 ppm CaCO
3
15 mm compression. Adjustable for top, bottom or rear
entry pipework.
1/2" BSP Male to flexible hose
230 - 240 V, 50 Hz
9.8 kW model (230 V = 9.0 kW, 240 V = 9.8 kW)
10.8 kW model (230 V = 9.9 kW, 240 V = 10.8 kW)
Continuously rated.
16 mm²
30 mA tripping current
Double-pole with 3 mm contact separation, 45 A
9.8 kW model = 40 A
10.8 kW model = 45 A
IP X4 - Suitable for installation in Zone 1
2°C
30°C
363 mm
270 mm
110 mm
6