Siemens F IWLAN Operating Instructions Manual page 49

Hmi device wireless teach pendant v2
Table of Contents

Advertisement

Testing mechanical ambient conditions
The following table provides information on the type and scope of tests for mechanical
ambient conditions performed for the HMI device.
Test
Vibrations
IEC 60068-2-6
Test Fc
Shock
IEC 60068-2-27
Impact
IEC 60068-2-75
Drop test
EN 60068-2-31
Climatic ambient conditions for the HMI device
The following table shows the permitted ambient climatic conditions for use of the HMI
device.
Ambient condition
Operating temperature
Humidity, relative
Humidity, absolute
Atmospheric pressure
Pollutant concentration
Wireless Teach Pendant F IWLAN V2
Operating Instructions, 08/2010, A5E02453837-01
Physical variable
Vibration
Frequency band
Shock form
Shock amplitude
Shock duration
Number of shocks
Impact stress
Fall height
Permitted range
0 to 40° C
5 to 85 %,
no condensation
1 to 25 g/m
3
1060 to 700 hPa
SO
< 0.5 vpm,
2
relative humidity < 60%,
no condensation
H
S < 0.1 vpm,
2
relative humidity < 60%,
no condensation
PRELIMINARY II
Planning the use
3.2 Operating conditions
Value
1 octave/min
10 cycles per axis
5 to 8.4 Hz:
Deflection 3.5 mm
8.4 to 150 Hz
Vibration acceleration 9.8 m/s
Half sine
15 g
11 ms
3 per axis
1 Nm, once
With an impact test device similar to
DIN VDE 0740, Part 1, Section 19.2 at
room temperature.
0.5 m
Applies to the HMI device, with and
without battery
Comment
Stress level 2,
according to IEC 61131-2
Corresponds to an
elevation of –1000 to 2000 m
Test: 10 cm
/m
; 10 days
3
3
Test: 1 cm
/m
; 10 days
3
3
1.7.2010
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic hmi

Table of Contents