evohome Controller
(ATC928G2000)
To bind a Radiator Controller (HR80) to an evohome
Controller (ATC928G2000) "radiator valve" zone...
On the evohome Controller
Press and hold
SETTINGS
1
Press the green tick
2
Press
ZONE SETTINGS
3
Press
EDIT ZONE
4
Press on the required zone
5
Press the button next to "Application:"
6
RADIATOR VALVE
Press
7
On the Radiator Controller
Press the recessed bind button on the
8
underside of the Radiator Controller – it should
briefly show a flashing RF icon
evohome Controller (ATC928G2000)
for 5 seconds
then SYNC.
Radiator Controller
Press the recessed bind button again – it
9
should show a flashing RF icon
On the evohome Controller
Press the bind button
10
The evohome Controller will not show a SUCCESS
message. It's recommended to perform a
quick functional check to validate the bind.
To do this, adjust the setpoint temperature on
the evohome controller for that zone to the
maximum and minimum, checking the radiator
controller responds to the new setpoint.