Drive Mode - Omron SYSDRIVE 3G3IV Installation Instructions Manual

High-performance/low noise general-purpose inverter
Table of Contents

Advertisement

3-2

Drive Mode

Depressing
DSPL
changes the display as follows:
POWER SUPPLY ON
FAULT DISPLAY
FREQUENCY REFERENCE
VALUE DISPLAY
OUTPUT FREQUENCY DISPLAY
OUTPUT CURRENT DISPLAY
RECORD OF
PAST FAULTS



*Check for display constants in APPENDIX at end of this manual
**Display changes every time
(display selection key)
If a fault occurs, its contents are displayed and blinks for 5 sec-
onds.
Set frequency is displayed. (If no fault occurs, this display is given
immediately at power supply ON, in 4 digits.)
Then the display changes as follows every time
key is depressed.
Frequency being output at present is displayed.
Inverter output current is displayed.
If a fault occurred before, its contents are displayed again.
(If no fault occurred, next constant is displayed.)
Monitor numbers such as output power are displayed.*
5-digit monitor value is displayed by depressing
Frequency set numbers such as master speed or inching are dis-
played.*
5-digit monitor value is displayed by depressing
DATA
key.
ENTER
Constant numbers that can be changed during operation, (such as
accel/decel time) are displayed.*
Monitor value is displayed by depressing
DSPL
DSPL
DATA
ENTER
DATA
ENTER
key is depressed.
Section 3-2
Operator
Display
(Typical main
circuit undervol-
tage trip)
key.
key.