Installation Instructions

Before installation

Be sure to configure the switches on the connector panel and bottom of the unit before installing it.
Configuring the switches after the unit is installed may prove difficult.

MODE switch settings

The MODE switches are located on the connector panel of the unit.
POWER/
10BASE-T/
STANDBY
RS-422
100BASE-TX
12V
ACT
LINK

How to install and connect the unit

Be absolutely sure to read through the "Read this first!" (→ pages 4 to 5) and "Installation precautions" (→ pages 6 to 7).

Performing the installation surface work

Perform the work to weld bolts to or drive anchors into the installation
surface.
This section describes the case of driving in anchors and fixing with
screws.
The dimensions of the installation parts (positions and hole diameter)
are shown below.
When fixing the camera directly to the installation
surface
Camera front
Image of AW-HR140 viewed from the bottom
<IMPORTANT>
• Check that the mounting installation surface is level.
• When welding anchor bolts to the installation surface, the length
of the cut threaded section should be 40 mm (1-9/16 inches) at
maximum and 30 mm (1-3/16 inches) at minimum.
Minimum withdrawal strength: 1764 N {180 kgf} per bolt
• Give sufficient consideration to corrosion and similar problems
by, for example, using screws with corrosion-resistant coating or
performing corking for the mounting screws between the camera or
mount bracket and body.
8
SDI OUT
G/L IN
1/PM
2
MODE
IN
EXT
SIGNAL GND
AUDIO IN(1/2)
MODE switch
Unit: mm (inch)
179.7 (7-1/16)
4 - ø 8.5 (ø 11/32)
Switch
positions
1
AW series protocol setting (Factory settings)
2
Standard protocol setting (baud rate 38400 bps)
3
Standard protocol setting (baud rate 9600 bps)
These are the positions for maintenance.
4
Do not use the unit while the switches are in these
positions.

Mounting the camera to the installation surface

When fixing directly to the installation surface
Spring washer and
flat washer, x4 of each
(supplied accessory)
<IMPORTANT>
• Pass the cables through the bottom wiring hole or side wiring hole
before putting the camera down on the installation surface.
Recommended clamping torque for mounting unit:
11.76 N·m {120 kgf·cm}
Minimum withdrawal strength of unit mounting bolts or mount
bracket mounting screws:
1764 N {180 kgf} per bolt
<NOTE>
• When a washer nozzle will be used, attach it to the washer nozzle
mount bracket (supplied accessory) in advance and then fix the
washer nozzle mount bracket in place when securing the camera
in the preceding "Mounting the camera to the installation surface"
(→ page 8).
Function
Unit mounting
bolt x4 (supplied
accessory)

Hide quick links: