Installation Instructions
How to install and connect the unit (continued)

Attaching the cable cover

Pass each of the cables (control cable, optional washer cable, etc.) to be
connected to the unit through the supplied cable cover.
Connect each of the cables to the respective connector at the rear of the
unit. (Refer to "Connections" (→ pages 12 to 16))
Connect the cable cover to the connector section at the rear of the unit
and fix it in place with the four screws.
<IMPORTANT>
• Securely tighten the four screws for attaching the cable cover to the
specified torque.
Otherwise, water entering inside will cause the unit to fail or fall.
Separately sold flexible conduit
Cables
Wrap self-adhesive tape around
When installing the unit in an environment in which the cables need to
be protected, provide a separately sold flexible conduit.
Select the following recommended flexible conduit or a flexible conduit
suitable for the outer diameter (ø 51 mm (ø 2 inches)) of the cable cover
back side and protect and waterproof the connections by wrapping self-
adhesive tape around.
Separately sold flexible conduit (recommended product)
Manufacturer:
Eco Solutions Company, Panasonic Corporation
Part no.:
Panasonic PV flexible conduit, nominal diameter
DMW128N (Panasonic PV flexible conduit)
<NOTE>
• Use weatherproof cables for outdoor wiring.
• If a cable protection tube will not be used, after passing the cables
through the cable cover opening, fill the opening with sealing putty and
then wrap self-adhesive tape around.
Cables
Cable cover
Sealing putty
10
Cable cover
Wrap self-adhesive tape around

Suspended installation

When installing the unit suspended by pole installation or other means
outdoors, provide a mount bracket of ø 350 mm (ø 13-25/32 inches) or
more that matches the dimensions in four places as a shelter against
rain and to prevent damage from birds.
For the structure of the mounting part, refer to "Performing the
installation surface work" (→ page 8).
Changing the rotation range (suspended
installation)
When the unit is installed suspended, the mechanism structure needs to
be switched over to enable rotation within the range of 175 degrees left
and right.
1.
Rotate the camera head to the position in the figure.
Front of body
<NOTE>
• Make sure the reinforcement arm cover is oriented toward the front of
the body.
If the work is performed when it is at another position, a load will be
applied to the cables inside the unit, leading to a failure.
2.
Loosen screw A and remove the reinforcement arm
cover from the body.
Reinforcement arm cover
Screw A (M4 with hexagon
socket head)
Camera head
Reinforcement arm cover