Mitsubishi LGH-15RX5-E Handbook page 23

Table of Contents

Advertisement

System
Classification
Details
Systems
Mitsubishi
interlock
City Multi
ed with
air condi-
external
tioner
device
(MA
(air con-
remote
dition-
controller
ing
or ME
units)
remote
controller)
Central
Central/in
control
depen-
system
dent con-
for
trol of
Lossnay
multiple
only
Lossnay
units
* Refer to the technical documentation for details about M-NET system design.
System Diagram
When using PZ-60DR-E
Lossnay
City Multi
Indoor unit
M-NET Remote
controller
MA
Lossnay remote controller
M-NET
(PZ-60DR-E)
transmission
(Operation without a remote
cable
controller is also possible.)
When using PZ-52SF-E
Lossnay
City Multi
indoor unit
Indoor unit
M-NET Remote
MA
R2
M-NET
Remote controller for M-NET
transmission
(PZ-52SF-E)
(Operation without a remote
cable
controller is also possible.)
Remote controller : Terminal block for trans-
mission cable between PZ-
60DR-E and Lossnay
M-NET
: M-NET transmission cable
terminal block
R1
: PZ-60DR-E
R2
: PZ-52SF-E
When using PZ-60DR-E
System controller
Power supply unit
SC
Power supply
Group 1
Lossnay
Lossnay
Lossnay
R1
Remote controller (PZ-60DR-E)
Group 3
Lossnay Lossnay
R1
When using PZ-52SF-E
Power supply unit
M-NET controller
SC
Power supply
Group 1
Lossnay
Lossnay
Lossnay
R2
Remote controller for M-NET
(PZ-52SF-E)
Group 3
Lossnay
Lossnay
R2
• Can be interlocked with a
maximum of 16 air condition-
ing units.
Transmission
• Lossnay can be
cable between
started/stopped, and
the remote
controller and
switched between High and
R1
Lossnay
Low fan speed by an air con-
ditioner remote controller.
• Lossnay stand-alone opera-
tion is permitted from an air
conditioner remote con-
troller.
• Having PZ-60DR-E or PZ-
52SF-E, last touch priority
controller
operation is permitted with
the air conditioner remote
controller and the Lossnay
remote controller.
*1: PZ-41SLB-E cannot be
*2: PZ-60DR-E and PZ-52SF-E
• Lossnay batch/independent
(group) control permitted by
system controller.
• Operation of Lossnay within
Group 2
a group is permitted by a
Lossnay remote controller.
Lossnay
(PZ-60DR-E or PZ-52SF-E)
• One group of a maximum of
R1
16 Lossnay units can be
operated.
Group 4
• Number of Lossnay control
units
Lossnay Lossnay
Centralized controller (AG-
150A) : 50 units/50 groups
R1
ON/OFF remote controller
(PAC-YT40ANRA) : 50
units/16 groups
System remote controller
Group 2
(PAC-SF44SRA) : 50
units/50 groups
Lossnay
*1: The remote controller (PZ-
R2
*2: PZ-60DR-E and PZ-52SF-E
Group 4
Lossnay
Lossnay
R2
— 23 —
Features
used in this system.
cannot be used together.
41SLB-E) cannot be used
in this system.
cannot be used together.
Prepared
Parts
• Lossnay
remote
controller
(PZ-60DR-
E or PZ-
52SF-E)
• Centralized
controllers
(G-50A),
(PAC-
SF44SRA),
(PAC-
YT40ANR
A), and
(AG-150A)
• Power sup-
ply units
(PAC-
SC50KUA),
(PAC-
SF46EPA),
and (PAC-
SC51KUA)