Horizontal Venting With Two (2) 90° Elbows; Horizontal Venting With Three (3) 90° Elbows - Regency P40-LP1 Specification Sheet

Direct vent gas fireplace
Table of Contents

Advertisement

Horizontal Venting
with Two (2) 90° Elbows
Two 45° elbows = One 90° elbow
Option
V
H+ H1
A)
2' Min.
2' Max.
B)
3' Min.
5' Max.
C)
4' Min.
6' Max.
D)
5' Min.
7' Max.
E)
6' Min.
8' Max.
Horizontal Venting
with Three (3) 90° Elbows
Two 45° elbows = One 90° elbow
Option
V
H
V+ V1
A)
0' Min.
1' Max.
1' Min.
B)
1' Min.
2' Max.
3' Min.
C)
2' Min.
2' Max.
5' Min.
D)
3' Min.
2' Max.
7' Min.
E)
4' Min.
3' Max.
9' Min.
F)
5' Min.
4' Max.
10' Min.
G)
6' Min.
5' Max.
11' Min.
H)
7' Min.
6' Max.
12' Min.
June 2007 Regency Product Specifi cations Book
Gas Fireplaces
Maximum total pipe: length, of
all sections, must not exceed
30 feet.
Total horizontal sections must
not exceed 8 feet.
Minimum of 1' pipe section
between any elbows.
When the total vertical
exceeds total horizontal by
2x then the vent restrictor
must be set to 1.
H + H1
Maximum total pipe:
length, of all sections,
1' Max.
must not exceed 30 feet.
Total horizontal sections
3' Max.
must not exceed 9 feet.
4' Max.
Minimum of 1' pipe
section between any
5' Max.
elbows.
6' Max.
When the total vertical
exceeds total horizontal
7' Max.
by 3x then the vent
8' Max.
restrictor must be set
to 1.
9' Max.
P40 Gas Fireplace