Download Print this page

Horizon Fitness Andes 3 Service Manual page 11

Hide thumbs Also See for Andes 3:

Advertisement

CHAPTER IV
No power to the console
Symptom:
Console does not light up.
Reason:
1. Adaptor not correct or defective.
2. Console cable defective.
3. Console defective.
Solution:
1. The adaptor for this model is 12V -1A. Ensure to use the correct specification of an adaptor,
and replace the adaptor if it is defective.
2. Unplug the console cable from PCB, and use a multi-meter to check output of console cable
Normally it shall be DC12V. If no output, the console cable defective, and replace it.
If output is DC 12V, the console PCB defective, and replace the console set.
(console cable's connectors with PCB)
TROUBLESHOOTING

Advertisement

loading