What To Do If - Roland CAMM-1 User Manual

Desktop sign maker
Hide thumbs Also See for CAMM-1:
Table of Contents

Advertisement

6 What to do if...

If the CM-24/12 doesn't run...
Is the CM-24/12 power on?
Turn on the power (refer to "3-4 Turning on the Power").
Is the unit in SETUP status (the SETUP LED is lit)?
If the SETUP LED is not illuminated, make sure the sheet is
loaded correctly and press the SETUP key to illuminate the
SETUP LED.
Is the PAUSE LED illuminated?
If the PAUSE key has been pressed and the PAUSE LED is lit
up, the unit has been paused (refer to "3-8 Downloading
Cutting Data Pausing Cutting Operations").
resume cutting, press the PAUSE key again. The PAUSE LED
is extinguished, and cutting resumes. If you want to termi-
nate cutting, first stop the transmission of cutting instructions
from the computer to the CM-24/12. Then press the SETUP
key. This deletes the cutting instructions that have already
been sent from the computer to the CM-24/12, and cutting is
stopped.
If connected via the serial port, do the communication
parameters for the CM-24/12 match those of the com-
puter?
Set the DIP switches correctly (refer to "3-2 DIP Switch
Settings").
Is the computer set up correctly?
Check the following items:
- DIP switches
- Memory switches
- Interface board
- Communication parameters
- Other settings
Read the computer user's manual and set it up correctly.
The POWER/ERROR LED is blinking
If there is an error in the data downloaded to the CM-24/12 from the computer, the CM-24/12 generates an error (the POWER/ERROR
LED begins to blink), and cutting cannot be carried out. The error can be canceled by switching off the power. After turning off the
power, check the following.
If you are using application software, has the correct
output device been selected? (Using with MS-DOS.)
Select "CM-24/12" as the output device. If this selection is
not available, select any model in the PNC-960, PNC-910,
PNC-950, PNC-900, or PNC-1100.
If you are using a program that you have created
yourself, have correct commands been sent?
The CM-24/12 is equipped with the CAMM-GL III instruction
system. For more details, see "7 Instruction Support Chart"
and the separately available "CAMM-GL III Programmer's
Manual."
Are the computer and the CM-24/12 linked with the right
cable?
The type of cable you need is determined by your computer
and the software you are using. Even if the computer is the
same, running different software may require a different cable.
Use the cable specified in your software.
Is the cable making a secure connection?
Connect securely (refer to "3-1 Setting Up and Connection").
Are the application software settings correct? (Using
with MS-DOS.)
If you want to
Check the following items:
Has the correct driver selection been made for the
application software? (Using with Windows.)
Select the appropriate CM-24/12 driver.
Are the settings for the driver software correct? (Using
with Windows.)
Make the correct settings for the output port and communica-
tion parameters.
Does the connecting cable match the settings for the
application software and the computer?
Refer to the operation manuals for your application software
and computer to select and connect the appropriate cable.
- Output device specifications (select a device name that
matches the instruction system. If the wrong device is
selected an incorrect instruction may be output, resulting
in an error).
- Communication parameters
- Other settings Check the software user's manual and set
it up correctly.
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cm-24Cm-12

Table of Contents