General Zone Options; Miscellaneous System Options; System Timers; Worksheet 56: System Timers - Paradox Magellan MG5000 Programming Manual

32-zone wireless transceiver security spectra sp series magellan series systems and 32-zone wireless transceiver security systems
Hide thumbs Also See for Magellan MG5000:
Table of Contents

Advertisement

Magellan & Spectra SP • Programming Guide
Table 62: Description of options 3 & 4 and 6 & 7, in section [705]
Option
3
4
RF Zone/Hardwired Zone Tamper Recognition Options
OFF
OFF
Disabled
OFF
ON
Trouble only
ON
OFF
When disarmed: trouble only; when armed: follow zone's alarm type
ON
ON
When disarmed: audible alarm; when armed: follow zone's alarm type
6
7
RF Zone Supervision Options
OFF
OFF
Disabled
OFF
ON
Trouble only
ON
OFF
When disarmed: trouble only; when armed: follow zone's alarm type
ON
ON
When disarmed: audible alarm; when armed: follow zone's alarm type
* Tamper recognition of keypad/bus module, only if section [700], option 7, is enabled.

General Zone Options

Table 63: Description of section [706]
Option
1
Check-in supervision time
2
EOL resistors (applies to all hardwired zones – panel, keypad, ZX8)
Zone input 1 becomes a two-wire smoke input (except SP4000, SP5500, and SP65) 
3
4
ZX8 ID A (panel + 1) input 1
5
ZX8 ID B (panel + 9) input 1
6
ZX8 ID C (panel + 17) input 1
= Default

Miscellaneous System Options

Table 64: Description of section [708]
Option
1
Enter code to view trouble
2
Enter code to view alarm in memory/event list
3
Trouble latch
4
Bell squawk on Installer in
5
Acknowledge trouble(s) before arming
6
Do not arm if zone opens during exit delay
7
Disable 'Bypass and Arm'
8
Future use
= Default

System Timers

Worksheet 56: System Timers

Section
Data
[710]
___/___/___ 000 to 255 seconds Entry delay 1* (default: 045)
[711]
___/___/___ 000 to 255 seconds Entry delay 2* (default: 045)
[712]
___/___/___ 000 to 015
[713]
___/___/___ 000 to 255 seconds Intellizone delay (default: 048)
[714]
___/___/___ 000 to 255 minutes Recycle alarm delay (default: 000)
[715]
___/___/___ 000 to 255
Version 4.7/4.92/5.12
Description
Description
Description
Auto-zone shutdown counter
(default: 005)
Recycle alarm counter
(default: 000)
Description
Keypad/Bus Module Tamper Recognition Options*
Disabled
Trouble only
Trouble only
Audible alarm
Keypad/Bus Module Supervision Options
Disabled
Trouble only
Trouble only
Audible alarm
OFF
24 hours
Disabled
Disabled
 Tamper input
Zone input
 Tamper input
Zone input
 Tamper input
Zone input
OFF
One-touch
One-touch
Disabled
Disabled
Disabled
Disabled
Disabled
-
-
-
Section
Data
[718]
___/___/___ 000 to 255 seconds
[719]
___/___/___ 000 to 255 days
[720]
___/___/___ 000 to 255 seconds Flex-instant delay (default: 015)
[721]
___/___/___ 000 to 255 seconds
[722]
___/___/___ 000 to 255 seconds
[723]
___/___/___ 000 to 255 seconds
* For EN 50131, the maximum value is 45 seconds.
** For EN 50131, the section must be set to a minimum of 3 and a maximum of 10
ON
80 minutes
Enabled
Enabled
ON
Enter code
Enter code
Enabled
Enabled
Enabled
Enabled
Enabled
-
Description
Remote panic disarm lock delay
(default: 000)
Closing delinquency delay
(default: 000)
For StayD: re-arm delay
(default: 005)
Auto trouble shutdown**
(default: 010)
Panic shutdown**
(default: 010)
Appendix A | 69

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents