Magellan & Spectra SP • Programming Guide

PCB Layouts/Wiring Diagrams

MG5000

12
Self-Contained Bell Connection
+
TRIGGER
-
+
-
SELF-CONTAINED
BELL/SIREN
1 Used for connecting the IP100 Internet Module; also used for In-Field
Firmware upgrade through a 307USB Direct Connect Interface
2 EBUS and Dialer used with:
VDMP3 Plug-in Voice Module for voice reporting
PCS Series GSM Communicator Module
3
LEDs
Charge LED:
Charging and battery test
Status LED:
Flash once every second: Normal
Flashes ON 1 sec. and OFF 1 sec.: Any trouble
Always ON: Panel is using phone line
Fast flash 6 seconds after power-up: Installer lock enabled
RX & TX LED:
Flashes quickly when receiving or transmitting RF signals from
wireless devices
4 Four-pin connector can be used for quick installation of a keypad
5 Antennas
The sum of the current drawn from the
and lead to complete system shutdown.
40 VA transformer strongly recommended.
This equipment must be installed and maintained by qualified service personnel only.
For UL and C-UL warnings, refer to the UL and C-UL Warnings section at the back of the MGSP Reference & Installation Manual.
Max. number of keypads: 15 keypads
Max. aux. current: 700 mA
Max. distance of bus module from panel: 76 m (250 ft.)
Max. total run of wire: 230 m (750 ft.)
Version 4.7/4.92/5.12
1
2
3
CHARGE
STATUS
RX
TX
RESET
SERVICE
KEYPAD
RED BLK
-
-
+
+
BATT
AC
PGM1PGM2
BELL
AUX
GRN YEL
11
10
9
8
19
and
must be limited to 1.3A. Exceeding this limit will overload the panel power supply
BELL
AUX
4
SERVICE
KEYPAD
Z1
C
Z2
GND
R-1
T-1
RING TIP
7
Teclado Magellan
18
6 Paradox Memory Key (PMC-4, PMC5)
7 Refer to Hardware Connections on page 59
8 The
output will shutdown if the current exceeds 3A
BELL
9 Refer to Alarm Relay and PGM Connections on page 60
10 16.5 Vac (50 or 60 Hz), minimum 20 VA (40 VA recommended)
11 Refer to AC Power & Backup Battery Connections on page 60
12 Refer to Panel Reset on page 3
13 AWG #14 single conductor solid copper wire
14 Ground clamp
15 Cold water pipe grounding
16 To metallic enclosure
17 For the keypad's zone configurations, see Installer Quick Menu on page 7
18 If EOL is enabled, see section [706] option 2, on page 38; for the keypad's
zone configurations, see Installer Quick Menu on page 7
19 To connect additional wiring to auxiliary power, use the red (+) and black
(-) keypad connectors; auxiliary power will shut down if current exceeds
1.1A; if the auxiliary output is overloaded and shuts down, you must
disconnect all loads from the output for at least 10 sec. before
reconnecting any load back to the auxiliary output
Do not cut, bend, or alter
5
the antennas, and ensure
that electrical wires do not
cross over them, as this
may affect signal
ANT
reception.
To provide maximum
lightning protection we
strongly recommend having
separate earth connections
for the dialer and zone
ground terminals.
6
Disconnect telephone line
RJ31X
before servicing.
CA 38A
14
13
15
16
17
PCB Layouts/Wiring Diagrams | 61