Sp4000 - Paradox Magellan MG5000 Programming Manual

32-zone wireless transceiver security spectra sp series magellan series systems and 32-zone wireless transceiver security systems
Hide thumbs Also See for Magellan MG5000:
Table of Contents

Advertisement

Magellan & Spectra SP • Programming Guide

SP4000

BATT
RED BLK
9
6
16
1
port used for GSM reporting using the PCS Series GSM
EBUS
Communicator Module; if using a CVT485 Plug-In RS485 Converter,
connect the PCS module to the RS485 bus;
and
port used for voice reporting with the VDMP3 Plug-in
DIALER
EBUS
Voice Module.
2 Paradox Memory Key (PMC-4, PMC5)
3 Used for connecting the IP100 Internet Module; also used for In-Field
Firmware upgrade through a 307USB Direct Connect Interface
4 Status LED:
Flash once every second: Normal
Flashes ON 1 sec. and OFF 1 sec.: Any trouble
Always ON: Panel is using phone line
Fast flash 6 seconds after power-up: Installer lock enabled
5 Refer to Hardware Connections on page 59
6 The
output will shutdown if the current exceeds 3A
BELL
7 Refer to Alarm Relay and PGM Connections on page 60
The sum of the current drawn from the
and lead to complete system shutdown.
40 VA transformer strongly recommended.
This equipment must be installed and maintained by qualified service personnel only.
For UL and C-UL warnings, refer to the UL and C-UL Warnings section at the back of the MGSP Reference & Installation Manual.
Max. number of keypads: 15 keypads
Max. aux. current: 450 mA
Max. distance of bus module from panel: 76 m (250 ft.)
Max. total run of wire: 230 m (750 ft.)
Version 4.7/4.92/5.12
-
+
-
+
AC
PG1
BELL
AUX
GRN YEL
1
8
7
and
must be limited to 1.3A. Exceeding this limit will overload the panel power supply
BELL
AUX
1
2
MEM KEY
SERIAL
STATUS
C
2
3
C
4
GND
R-1
T-1
RING TIP
5
11
10
Keypad
8 16.5 Vac (50 or 60 Hz), minimum 20 VA (40 VA recommended)
9 Refer to AC Power & Backup Battery Connections on page 60
10 Connect to any common input
11 AWG #14 single conductor solid copper wire
12 Ground clamp
13 Cold water pipe grounding
14 To metallic enclosure
15 For the keypad's zone configurations, see Installer Quick Menu on page 7;
If EOL is enabled, see section [706] option 2, on page 38
16 To connect additional wiring to auxiliary power, use the red (+) and black
(-) keypad connectors; auxiliary power will shut down if current exceeds
1.1A; if the auxiliary output is overloaded and shuts down, you must
disconnect all loads from the output for at least 10 sec. before
reconnecting any load back to the auxiliary output
Panel Reset
To perform a panel reset, see Panel Reset on page 3.
To provide maximum
lightning protection we
strongly recommend
3
having separate earth
4
connections for the dialer
and zone ground
terminals.
Disconnect telephone
RJ31X
line before servicing.
CA 38A
12
13
14
15
PCB Layouts/Wiring Diagrams | 63