Magellan & Spectra SP • Programming Guide

Automatic Report Codes

Table 45: List of automatic report codes
Arming with user code (##)
Disarm with user code (##)
Disarm after alarm with user code (##)
Cancel alarm with user code (##)
Auto arming cancellation
Disarm with PC software
Disarm after an alarm with PC software
Cancel alarm with PC software
Cancel paramedic alarm
Keyswitch disarm after alarm
Keyswitch cancel alarm
Zone alarm restore (##)
24-hr water alarm (##)
24-hr freeze alarm (##)
24-hr gas alarm restore (##)
24-hr heat alarm restore (##)
24-hr water alarm restore (##)
24-hr freeze alarm restore (##)
24-hr hold-up alarm restore
Global zone shutdown
Zone tamper restore (##)
Auxiliary supply trouble
Bell output current limit
Version 4.7/4.92/5.12
System Event Default Contact ID Report Code
3 4A1
Auto arming
3 4A3
Late to close
3 452
No movement
3 452
Partial arming
1 456
Quick arming
3 4A8
Arm with PC software
3 4A7
Keyswitch arming
3 4A9
1 4A1
1 4A1
1 4A6
1 464
1 4A7
1 4A7
1 4A6
1 4A6
Keyswitch disarm
1 4A9
1 4A1
1 4A6
Zone bypassed (##)
1 57A
Zone alarm (##)
1 13A
Fire alarm (##)
1 11A
3 13A
Fire alarm restore (##)
3 11A
24-hr gas alarm (##)
1 151
24-hr heat alarm (##)
1 153
1 154
1 152
3 151
3 153
3 154
3 152
24-hr hold-up alarm
1 12A
3 12A
Panic 1: emergency
1 12A
Panic 2: medical
1 1AA
Panic 3: fire
1 115
Recent closing
3 459
1 575
Duress alarm
1 121
Keypad lockout
1 421
Zone shutdown (##)
1 57A
Zone tampered (##)
1 144
3 144
TLM Trouble
1 351
AC failure
1 3A1
Battery failure
1 3A9
1 3AA
1 321
Close by user
Automatic close
Late to close
Late to close
Group bypass
Quick arm
Remote arm/disarm
Keyswitch arming
Open by user
Open by user
Cancel by user
Deferred open/close
Remote arm/disarm
Remote arm/disarm
Cancel by user
Cancel by user
Keyswitch disarm
Keyswitch disarm after alarm
Keyswitch cancel alarm
Zone bypass
Burglary alarm
Fire alarm
Burglary alarm restore
Fire alarm restore
Gas detected
Loss of heat
Water leakage
Refrigeration
Gas restore
Heat restore
Water restore
Freeze restore
Panic alarm
Panic alarm restore
Panic alarm
Medical alarm
Pull station
Open/close
Group bypass
Duress
Access denied
Zone bypass
Sensor tamper
Sensor tamper restore
Telco 1 fault
AC loss
Battery test failure
System trouble
Bell 1
Default SIA Report Code
CL
Closing report
CA
Automatic closing
OT
Late to close
NA
No activity
CG
Close area
CL
Closing report
CQ
Remote arming
CS
Keyswitch arming
OP
Opening report
OP
Opening report
OR
Disarm from alarm
CE
Closing extend
OQ
Remote disarming
OR
Disarm from alarm
OR
Disarm from alarm
MH
Medical alarm restore
OS
Keyswitch disarm
OS
Keyswitch disarm after alarm
OS
Keyswitch cancel alarm
UB
Untyped zone bypass
BA
Burglary alarm
FA
Fire alarm
BH
Burglary alarm restore
FH
Fire alarm restore
GA
Gas alarm
KA
Heat alarm
WA
Water alarm
ZA
Freeze alarm
GR
Gas alarm restore
KR
Heat alarm restore
WR
Water alarm restore
ZR
Freeze alarm restore
PA
Panic alarm
PR
Panic restore
PA
Panic alarm
MA
Medical alarm
FA
Fire alarm
CR
Recent closing
CG
Close area
HA
Hold-up alarm
JA
User code tamper
UB
Untyped zone bypass
TA
Tamper alarm
TR
Tamper restoral
LT
Phone line trouble
AT
AC trouble
YT
System battery trouble
YP
Power supply trouble
YA
Bell fault