Gps Connection - Raymarine C90W Installation Manual

C-series widescreen multifunction display
Hide thumbs Also See for C90W:
Table of Contents

Advertisement

High alarm loads and third party alarms
You can use the alarm output to switch a relay. This may be useful
for connecting high loads such as third party alarm sounders or
inductive loads to the C-Series multifunction display. If you are in
any doubt as to how to make such connections please consult an
authorized installer.
The C-Series multifunction display has a positive switched alarm
output. The following circuit shows the arrangement for connection
of a relay switch.
Alarm output configured to switch a relay
Alarm out
(+ve)
Suppression
diode
0v return
Note: When connecting the output to a relay or other inductive
device you should fit a spike suppression diode e.g. 1N4001.
Cables and connections
Battery +
Relay
High current load
Battery --

3.8 GPS connection

Depending upon your GPS type it may be either connected via
SeaTalk or NMEA 0183.
See also
• For SeaTalk connection refer to:
• For NMEA 0183 connection refer to:
3.6 SeaTalk
connection.
3.5 NMEA 0183
connection.