11.12.3 EMERGENCY OPERATION
•
If you do not have the infrared remote control (because the batteries are weak, or some other reason prevents
the infrared remote control from being used), the emergency operation can be carried out at the receiver.
•
Press the AUTO switch to start the emergency operation. Press the AUTO switch once more to stop the
emergency operation.
•
Press the AUTO switch for 5 seconds or more (it will beep once) to start the cooling operation. Again, press the
AUTO switch for 5 seconds or more (it will beep twice) to start the heating operation.
•
The setting of the fan speed and louver control will be fixed as shown by the table below.
•
While the indoor unit is running, the POWER indicator on the infrared receiver will illuminate, and it will light off
when the indoor unit stops.
•
Heating operation is not available for indoor units which are for cooling only.
INSTRUCTIONS FOR USERS
Please refer to the instruction manual provided with the indoor unit for instructions on how to use the infrared remote
control.
AUTO switch
Infrared Receiver
Operation mode
Cooling
Heating
Fan speed
Hi
Previous setting
Hi
Previous setting
156
Louver