KitchenAid KUIS155H Technical Education page 67

15" & 18" automatic ice makers
Table of Contents

Advertisement

1 to 16 minutes, dependent on the condition of the evaporator thermistor.
Harvest Mode:
NOTE: Each path is possible and acceptable at any temperature range. A typical operation
is shown below that may be found at a particular ambient temperature.
Warmer Ambients
(Above 90°F)
Move this directio n
if /when evap.
ther misto r is
greater th an
Compressor, Fan
& Water Valve
are energized
(1 minute)
1 minute has
elapsed
Check ice level
(The control reads
the bin thermistor)
Bin is not full
Freeze Mode
(See page 6-8)
Unit leaves the
Compressor, Hot Gas &
Water Valves are
energized (time will be
0 to 1 minute maximum)
52
F
°
Evap. th ermist or is greater
than
or 3 minu tes
52°F
have elapsed wi thout
sen si ng the evap. thermist or
Evap. thermistor is greater
52
than
Bin is full
Freeze Mode
Move this directio n if the
evap. th ermist or remains l ess
than 52°F and 1 minute has
Compressor & Hot Gas Valve are energized
(3 minutes if evaporator thermistor is less
than 52°F or not sensed)
Compressor & Hot Gas Valve are energized
(12 minutes if evaporator thermistor remains
F
°
12 minutes have elapsed.
The Compressor & Hot Gas Valve
will have been on a total of 16
Idle Mode
(See page 6-7)
6-9
Cooler Ambients
(Below 90°F)
elapsed
3 minutes have elapsed
with evap. thermistor
52
F
°
less than
less than 52°F)
minutes at this point
Harvest Fail
(See Failure Mode
on page 6-10)

Hide quick links: