Water Recirculation Pump; Condenser Fan Motor - KitchenAid KUIS155H Technical Education

15" & 18" automatic ice makers
Table of Contents

Advertisement

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

WATER RECIRCULATION PUMP

Refer to page 4-7 for the procedure for servic-
ing the water recirculation pump.
1.
Unplug ice maker or disconnect power.
2.
Set the ohmmeter to the R x 100 scale.
3.
Touch the ohmmeter test leads to the
outside water recirculation pump wire con-
nector pins. The meter should indicate
between 17 and 23 Ω.
WARNING
Electrical Shock Hazard

CONDENSER FAN MOTOR

Refer to page 4-8 for the procedure for servic-
ing the condenser fan motor.
1.
Unplug ice maker or disconnect power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter test leads to the
outside pins of the condenser fan motor
connector. The meter should indicate be-
tween 265 and 285 Ω.
5-3