Valve Adjustments - Function Manifold - Genie GR-12 Service Manual

Table of Contents

Advertisement

Service Manual
Function Manifold
4-2
Valve Adjustments -
Function Manifold
Note: Perform this test from the ground with the
platform controls. Do not stand in the platform.
Note: Verify the hydraulic oil level is at the FULL
mark on the hydraulic tank.
How to Adjust the System Relief
Valve
1
Locate the system relief valve on the function
manifold (schematic item I).
1 test port
2 system relief valve
2
Connect a 0 to 5000 psi / 0 to 350 bar
pressure gauge to the test port on the function
manifold (schematic item A).
64
3
Chock both sides of the wheels at the steer
end of the machine.
4
Remove the platform controls from the
platform.
5
Turn the key switch to platform controls and
pull out the red Emergency Stop button to the
on position at both ground and platform
controls.
6
Move and hold the joystick fully in either
direction while observing the pressure reading
on the pressure gauge. Note the pressure.
Refer to Specifications, Hydraulic Component
Specifications.
7
Turn the machine off. Hold the system relief
valve with a wrench and remove the cap
(schematic item I).
8
Adjust the internal hex socket. Turn it
clockwise to increase the pressure or
counterclockwise to decrease the pressure.
9
Install the relief valve cap.
10 Repeat steps 5 and 6 to confirm the relief
valve pressure.
GR
• QS
R • QS
W
May 2018
Part No. 1275811GT

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gr-15Gr-20Qs-20rQs-12wQs-15wQs-12r ... Show all

Table of Contents