How to Install and Calibrate the
Level Sensor - Procedure 2
Tip-over hazard. Failure to install
the level sensor as instructed will
compromise machine stability
and cause the machine to tip
over, resulting in death or
serious injury. Do not install the
level sensor other than specified
in this procedure.
Note: If you are not installing a new level sensor,
proceed to step 8.
1
Move the machine to an area that has a firm,
level surface and is free of obstructions.
Note: The surface must be 0° +/- 0.5°.
2
Tag and disconnect the level sensor wire
harness from the chassis wire harness.
3
Remove the level sensor retaining fasteners
and remove the level sensor from the
machine.
Part No. 1275811GT
4
Place the new level sensor on to the level
sensor bracket with the "X" on the level sensor
towards the steer end of the machine.
1 drive chassis
2 X axis
3 level sensor
4 mast
GR
• QS
R • QS
W
Service Manual
Ground Controls
Tip-over hazard. Failure to install
the level sensor as instructed,
could result in the machine
tipping over, causing death or
serious injury.
Steer End
Non-steer End
55