Connecting the open array scanner cable

CAUTION:
Before wiring the scanner unit check that it is securely mounted to
the platform, then make sure that the inter-unit cable is not
connected and power is not applied to the display unit. The
scanner switch must be in the OFF position.
Connection of the Pathfinder inter-unit cable and the C-series split pedestal cable is
Note:
identical.
1. Loosen the four self-retaining bolts securing the pedestal lid to the base. Pull-
up and turn the bolts anti-clockwise to lock them in the upright position.
Remove the lifting eyes.
It is important to remove lifting eyes to avoid corrosion. Retain the lifting eyes: they
Note:
will be required if the scanner is removed from its platform.
2. Open the pedestal lid. Ensure the securing stay has automatically locked into
position.
3. Referring to the following illustration, remove the cable gland nut, washer
and grommet from the watertight gland, where the cable will enter the base.
4. Slide the cable through the gland nut, washer and grommet, then into the
base. Carefully remove the heat shrink shroud, ensuring that you do not dam-
age the cable.
Pathfinder Radar Scanners
Pedestal
IMPORTANT
Bitumen washer, MUST
be sticky side down
on mounting
platform
Mounting
platform
M10 stud
length = 52 mm
plus platform depth
M10 plain washer
M10 spring washer
M10 nut
D4573-4