Problem Solving - Raymarine Raychart 320 Owner's Handbook Manual

Chartplotter
Hide thumbs Also See for Raychart 320:
Table of Contents

Advertisement

Chapter 6: Maintenance & Fault Finding
4. Either hold the MENU key until the countdown timer times out or
Note:

6.3 Problem Solving

Prior to packing and shipping, all Raymarine products are subjected to
comprehensive test and quality assurance programs. However, should
this unit develop a fault, refer to Table 6-2 to identify the most likely
cause and the corrective action required to restore normal operation.
If you still have a problem, contact your local dealer, national distributor
or Raymarine Product Support for further advice.
Always quote the product serial number.
Table 6-2: Fault Finding Guide
Problem
Unit does not function
Poor display definition
No fix
No NMEA data
received
Loss of stored data
eg. waypoints
No detailed chart data
Other problems
release the MENU key to abort Factory Reset.
When the unit is reset, it restarts as for a first time Power Up with
all values reset to their original factory settings
The factory default settings are listed in Chapter 4.
Corrective Action
1 Make sure that the power supply cable is sound and that
all connections are tight and free from corrosion.
2 Check polarity of the DC power cables for proper connec-
tion.
Reconnect leads as necessary.
3 Check in-line fuse and replace as required.
4 Check vessel's power (battery) for correct voltage read-
ings (9.0VDC to 32.0VDC).
Adjust contrast setting and/or backlight level.
Check GPS Antenna connector.
Check that GPS Antenna is not obstructed.
Check POWER/NMEA connector and NMEA equipment.
Return to dealer for internal battery check.
Check that C-Card is securely fitted.
Check that C-Card contains appropriate cartography.
Visit our website: www.raymarine.com
6-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents