Technical Data - Rangemaster 90 User Manual

Rangemaster 90 dual fuel users guide installation & service instructions u104900-01
Table of Contents

Advertisement

Technical Data

This cooker is category II
It is supplied set for group H natural gas.
A conversion kit from NG to LP gas is included.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION:
Country of Destination: GB/IE
Gas
Natural Gas 20mbar
Butane
Propane
(See appliance data badge for test pressures)
Dimensions
Overall height
Overall width
Overall depth
Space for fi xing
Minimum space above hotplate
Connections
Gas:
1
Rp
/
at rear right-hand side
2
Ratings
Hotplate
Wok burner
Large Burner
Medium Burner
Small Burner
Gas burner inputs based on Gross Calorifi c Value
Ovens
Fan element
Top element
Browning Element
Bottom element
Grill
Maximum total electrical load at 230V
*approximate total including oven lights, oven fan etc.
Ovens
Energy effi ciency class
on a scale of A (more effi cient) to G (less effi cient)
Energy consumption based on standard load
Usable volume (litres)
Size
2H3+
Cooker back, serial number repeater badge below oven door opening.
Electric
220 - 240V 50Hz
29mbar
37mbar
minimum 898mm maximum 925mm
900mm
648mm
See 'Positioning of Cooker'
650mm
Electric
220 - 240V 50Hz
Natural Gas
Injector
3.65kW internal 80
external 129
3.0kW 134
1.7kW 109
1.0kW 75
Left hand Multifunction Oven
2.5kW
1.2kW
1.15kW
1.0kW
2.3kW
7.4kW*
See 'Positioning of Cooker'
L.P. Gas
3.5kW (246g/h) internal 54
3.0kW (210g/h) 87
1.7kW (119g/h) 68
1.0kW (70g/h)
Right hand Fan Oven
Multifunction
Forced air convection Tall Oven
B
0.90kWh
62
Medium
39
Injector
external 77
51
2.5kW
B
0.95kWh
53
Medium

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: