Toshiba RAS-10YKV-E Service Manual page 22

Split type
Hide thumbs Also See for RAS-10YKV-E:
Table of Contents

Advertisement

For INDOOR UNIT
220–230–240 V
~ 50/60 Hz
Discharge
temp. sensor
Outdoor air
temp. sensor
Suction temp.
sensor
Heat exchanger
temp.sensor
More user manuals on
ManualsBase.com
MICRO-COMPUTER BLOCK DIAGRAM
MCC808 (P.C.B)
Inddor unit
send/receive
M.C.U
circuit
• PWM synthesis function
• Input current release control
• IGBT over-current detect control
• Outdoor fan control
• High power factor correction control
• Inverter output frequency control
• A/D converter function
• P.M.V. control
• Discharge temp. control
• 4-way valve control
• Signal communication to indoor unit
High Power
factor Correction
circuit
Noise
Input current
Filter
sensor
Driver circuit
of P.M.V.
P.M.V.
Rotor position
detect circuit
Rotor position
detect circuit
Over current
detect circuit
Over current
sensor
Clock
frequency
16MHz
Converter
Over current
(AC
DC)
Relay
Over current
circuit
sensor
4-way
valve
OUTDOOR UNIT
Gate drive
circuit
Gate drive
circuit
Outdoor
Inverter
Fan motor
sensor
(DC
AC)
Inverter
(DC
AC)
Compressor

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-10yav-eRas-13ykv-eRas-13yav-e

Table of Contents