Judgment By Flashing Led Of Indoor Unit - Toshiba RAS-10YKV-E Service Manual

Split type
Hide thumbs Also See for RAS-10YKV-E:
Table of Contents

Advertisement

10-3. Judgment by Flashing LED of Indoor Unit

While the indoor unit monitors the operation status of the air conditioner, if the protective circuit operates, the
contents of self-diagnosis are displayed with block on the indoor unit indication section.
Indoor
indication
lamp flashes.
Which lamp
does flash?
NOTES :
(1) The contents of items B and C and a part of item E are displayed when air conditioner operates.
(2) When item B and C, and item B and a part of item E occur concurrently, priority is given to the block of item B.
(3) The check codes can be confirmed on the remote controller for servicing.
More user manuals on
Check
Item
code
OPERATION
ECONO.
A
TIMER
PRE DEF.
OPERATION
ECONO.
B
TIMER
PRE DEF.
OPERATION
ECONO.
C
TIMER
PRE DEF.
OPERATION
ECONO.
D
TIMER
PRE DEF.
OPERATION
ECONO.
E
TIMER
PRE DEF.
ManualsBase.com
Table 10-3-1
Block display
OPERATION (Green)
Flashing display (1 Hz)
OPERATION (Green)
Flashing display (5 Hz)
OPERATION (Green)
TIMER (Yellow)
Flashing display (5 Hz)
OPERATION (Green)
PRE DEF. (Orange)
Flashing display (5 Hz)
OPERATION (Green)
TIMER (Yellow)
PRE DEF. (Orange)
Flashing display (5 Hz)
– 42 –
Description for self-diagnosis
Power failure (when power is ON)
Protective circuit operation for
indoor P.C. board
Protective circuit operation for
connecting cable and serial signal
system
Protective circuit operation for
outdoor P.C. board
Protective circuit operation for others
(including compressor)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-10yav-eRas-13ykv-eRas-13yav-e

Table of Contents