Wiring Control Circuit Terminals - Omron SYSDRIVE 3G3FV-*-CUE Installation Manual

Table of Contents

Advertisement

Installation

2-2-5 Wiring Control Circuit Terminals

A control signal line must be 50 m maximum and separated from power lines. The fre-
quency reference must be input to the Inverter through twisted-pair wires.
H Wire Size and Round Solderless Terminals
Use thick wires to prevent voltage drops if the wires are long.
D Wires for All Inverter Models
Terminal
3G3FV
1 to 43
3G3HV
S1, S2, S3, S4, S5, S6, SC,
FV, FI, FS, FC, AM, AC, M1,
M2, MA, MB, MC
E (G)
D Solderless Terminals for Control Circuit Terminals
The use of solderless terminals for the control circuit terminals is recommended because solderless
terminals are easy to connect securely.
d1 dia.
d2 dia.
Note Do not solder wires with the control circuit terminals if wires are used instead of solderless termi-
nals. Wires may not contact well with the control circuit terminals or the wires may be discon-
nected from the control circuit terminals due to vibration if the wires are soldered.
D Round Solderless Terminals for Ground Terminal
Wire thickness
2
(mm
)
0.5
0.75
1.25
2
2-44
Terminal
screw
---
Stranded wire: 0.5 to 1.25
Single wire: 0.5 to 1.25
M3.5
0.5 to 2
Wire thickness
2
0.5 mm
2
0.75 mm
2
1 mm
2
1.5 mm
Terminal
screw
M3.5
1.25 to 3.5
1.25 to 3.5
1.25 to 3.5
2 to 3.5
www.dadehpardazan.ir 88594014-15
2
Wire thickness (mm
)
Model
A1 0.5-8WH
1.00
A1 0.75-8GY
1.20
A1 1-8RD
1.40
A1 1.5-8BK
1.70
Size
Chapter 2
Type
Shielded, twisted-pair wire
Shielded,
polyethylene-covered, vinyl
sheath cable
d1
d2
Manufacturer
Phoenix Contact
2.60
2.80
3.00
3.50

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysdrive 3g3hv-*-cueSysdrive 3g3hv-*-cue-ce

Table of Contents