Step 2: Cabinet Preparation
The range is a free standing
unit. If the unit is to
be placed
adjacent
to cabinets,
the clearances
shown
in Fig. 1 are required.
The same clear-
ances apply to island installations,
except for the
overhead
cabinets,
which
must have
a space
wide enough to accept the flared island hood, as
indicated
in Fig. 1.
These ranges may be recessed
into the cabinets
beyond the edge of the front face of the oven (See
Figures 2A and 2B).
Caution
In these installations,
the door and cabinet
can cause a pinching hazard.
.
5.
.
.
Any openings
in the wall behind the range and in
the floor under the range must be sealed.
When
there is less than a 12" horizontal
clear-
ance between
combustible
material
A and the
back edge of the range above the cooking
sur-
face,
a Thermador
Low
Back
or High
Shelf
backguard
must be installed.
(See Fig. 2A). When
clearance
to combustible
material
/_is over 12",
a Thermador
Island Trim may be used. (See Fig.
2B).
Figures
2A and 2B indicate
the space
required
for each type of backguard.
Always
keep appliance
area clear and free from
combustible
materials,
gasoline
and other flam-
mable vapors and liquids.
Do not obstruct
the flow of combustion
and ven-
tilation air to the unit.
3.
The gas and electrical
supply
should
be within
the zones shown in Fig. 3A.
Note:
The maximum
depth
of over head cabinets
installed
on either side of the hood is 13".
A 40-inch
minimum
clearance
is required
between
the top of the cooking
surface
and the bottom of an
unprotected
cabinet. A 30-inch minimum
distance
is
necessary
when
the bottom
of the wood
or metal
cabinet
is protected
by not less than 1/4 inch of a
flame retardant
material
covered
with not less than
No. 28 MSG sheet steel, 0.015 inch (0.4 mm) thick
stainless
steel,
0.024
inch (0.6 mm) aluminum,
or
0.020
inch (0.5 mm) thick copper.
Flame retardant
materials
bear the mark:
UNDERWRITERS
LABORATORIES
INC.
CLASSIFIED
MINERAL
AND FIBER
BOARDS
SURFACE
BURNING
CHARACTERISTICS
Followed
by the flame
spread
and smoke
ratings.
These
designations
are shown
as "FHC
(Flame
Spread/Smoke
Developed)."
Materials with "O" flame
spread ratings are flame retardant.
Local codes may
allow other flame spread ratings.