Step 2: Cabinet Preparation
GAS AND ELECTRIC
SUPPLY
F_G. 3A Gas & Electrica_
Supply
Locations
for All Gas Ranges
1 3/4" maximum I
from wall for gas or
electrical supply
electrical
supply zone
gas
supply zone
30 1/4" (30" models)
36 1/4" (36" models)
NOTE:
A Manual Gas ShutzOff Valve (not shown) must be easily accessible
through an adjacent cabinet without moving
the range.
NOTE: Any opening in the wall behind the appliance and any opening in the floor under the appliance must be sealed.
The All Gas ranges may be connected to the power supply with a range supply cord (supplied with range) or by hardz
wiring to the power supply. It is the responsibility of the installer to provide the proper wMng components (cord or conduit
and wires) and complete the gas connection as dictated bylocal codes and ordinances, and/or the National Electric Code.
The units must be properly grounded. Refer to Step 6 for details.
The range must be connected
only to the type of gas for wh{ch it is certified. If the range is to be connected to
propane gas, ensure that the propane gas supply tank is equipped with its own high pressure regulator in addition to
the pressure regulator supplied with the range. (See STEP 5.)
mMPORTANT:
The
cord supplied
with model
P34GE
gas range,
having
electdc
griddle,
requires
a NEMA 5-20 receptacle,
shown here. Local codes
may require a different
wiring method.
NEMA 5_20
RECEPTACLE