Step 2: Cabinet Preparation - Thermador Professional PRO-HARMONY PRD30 Installation Manual

Dual fuel ranges
Hide thumbs Also See for Professional PRO-HARMONY PRD30:

Advertisement

Available languages

Available languages

Range
Range Top
ao.
|
Width
Configuration
Ventilation Options
30" or 36" Pro Wall Hood
30"
4 burners
30" or 36" Custom Insert w/ optional blower
42" Island Hood w/ optional blower
4 burners with griddle
36" or 42" Pro Wall Hood
36"
36" Custom Insert w/ optional blower
6 burners
42" or 48" [sland Hood w/ optional blower
48" or 54" Pro Wall Hood**
48"
6 burners with griddle
;
48" Custom Insert w/ optional blower
Important Notes:
«
|tis recommended
that a Thermador
Professional wall or island hood or custom
insert is used with Thermador
Professional Ranges.
«
The HPWB
Professional Series Wall Hoods or the Professional Series Custom Inserts are recommended ventilation
solutions for these ranges. The PH Professional Series Wall Hoods are also a viable option, however the 27" depth of
the PH series may not be suitable to all applications.
*
Refer to www.Thermador.com for a complete selection of Professional Ventilation options, Blowers, and
Accessories.
*
For high output gas ranges (60,000 BTU or greater), the minimum of one (1) CFM of ventilation per 100 BTU is
recommended.
If the range has a griddle, add 200 CFM to the estimated blower capacity. Additional blower capacity
may be required for longer duct runs.
*
For island applications, it is recommended to use a hood width that exceeds the width of the range by 6" (overlapping
the range by a minimum of 3" on each end).
*
**Not all 48" Pro Wall Hood models can accommodate a 1,300 CFM blower option.
*
CFM = "cubic feet per minute" (standard blower capacity rating).
Step 2: Cabinet Preparation
1.
The range is a free standing unit. If the unit is to be
placed adjacent to cabinets, the clearances shown in
Figure 1 are required. The same clearances apply to
island installations, except for the overhead cabinets,
which must have a space wide enough to accept the
flared island hood, as indicated in Figure 1.
2.
These ranges may be recessed into the cabinets
beyond the edge of the front face of the oven (See
Figure 2 and Figure 3b).
CAUTION
In these installations, the door and cabinet can
cause a pinching hazard.
3.
The gas and electrical supply should be within the
zones shown in Figure 3a.
Note:
The maximum depth of over head cabinets installed on
either side of the hood is 13".
English 4
A 36-inch minimum clearance is required between the top
of the cooking surface and the bottom of an unprotected
cabinet. A 30-inch clearance can be used when the bottom
of the wood or metal cabinet is protected by not less than
1/4 inch of a flame retardant material covered with not less
than No. 28 MSG sheet steel, 0.015 inch (0.4 mm) thick
stainless steel, 0.024 inch (0.6 mm) aluminum, or 0.020
inch (0.5 mm) thick copper. Flame retardant materials bear
the following mark:
UNDERWRITERS LABORATORIES INC. CLASSIFIED
MINERAL AND FIBER BOARDS SURFACE BURNING
CHARACTERISTICS
Followed by the flame spread and smoke ratings. These
designations are shown as "FHC (Flame Spread/Smoke
Developed)." Materials with "O" flame spread ratings are
flame retardant. Local codes may allow other flame spread
ratings.
4.
Any openings in the wall behind the range and in the
floor under the range must be sealed.
5.
When
there is less than a 12" horizontal clearance
between combustible material A and the back edge of