Section 3.6.3

Configuring the Local System Log

To configure the severity level for the local system log, do the following:
NOTE
For maximum reliability, use remote logging. For more information, refer to
Remote Logging"
Navigate to Administration » Configure Syslog » Configure Local Syslog . The Local Syslog form appears.
1.
2
Figure 13: Local Syslog Form
1. Local Syslog Level    2. Apply Button    3. Reload Button
2.
Configure the following parameter(s) as required:
Parameter
Local Syslog Level
3.
Click Apply.
Section 3.6.4

Managing Remote Logging

In addition to the local system log maintained on the device, a remote system log can be configured as well to
collect important event messages. The syslog client resides on the device and supports up to 5 collectors (or syslog
servers).
The remote syslog protocol, defined in RFC 3164, is a UDP/IP-based transport that enables the device to send event
notification messages across IP networks to event message collectors, also known as syslog servers. The protocol
is designed to simply transport these event messages from the generating device to the collector(s).
CONTENTS
Section 3.6.4.1, "Configuring the Remote Syslog Client"
Section 3.6.4.2, "Viewing a List of Remote Syslog Servers"
Configuring the Local System Log
.
Description
Synopsis:   { EMERGENCY, ALERT, CRITICAL, ERROR, WARNING,
NOTICE, INFORMATIONAL, DEBUGGING }
Default:   INFORMATIONAL
The severity of the message that has been generated. Note that
the severity level selected is considered the minimum severity
level for the system. For example, if ERROR is selected, the system
sends any syslog messages generated by Error, Critical, Alert and
Emergency.