Upgrading Firmware; Downgrading Firmware - Siemens RUGGEDCOM ROS User Manual

Hide thumbs Also See for RUGGEDCOM ROS:
Table of Contents

Advertisement

RUGGEDCOM ROS
User Guide
Section 3.10.2, "Downgrading Firmware"
Section 3.10.1

Upgrading Firmware

Upgrading RUGGEDCOM ROS firmware, including the main, bootloader and FPGA firmware, may be necessary
to take advantage of new features or bug fixes. Binary firmware images are available from Siemens. Visit
www.siemens.com/ruggedcom
Support.
Binary firmware images transferred to the device are stored in non-volatile Flash memory and require a device
reset in order to take effect.
IMPORTANT!
Non-Controlled (NC) versions of RUGGEDCOM ROS can not be upgraded to Controlled firmware
versions. However, Controlled firmware versions can be upgraded to an NC firmware version.
NOTE
The IP address set for the device will not be changed following a firmware upgrade.
To upgrade the RUGGEDCOM ROS firmware, do the following:
1.
Upload a different version of the binary firmware image to the device. For more information, refer to
Section 3.5, "Uploading/Downloading Files"
2.
Reset the device to complete the installation. For more information, refer to
Device"
.
Access the CLI shell and verify the new software version has been installed by typing version. The currently
3.
installed versions of the main and boot firmware are displayed.
Section 3.10.2

Downgrading Firmware

Downgrading the RUGGEDCOM ROS firmware is generally not recommended, as it may have unpredictable
effects. However, if a downgrade is required, do the following:
IMPORTANT!
Before downgrading the firmware, make sure the hardware and FPGA code types installed in the
device are supported by the older firmware version. Refer to the Release Notes for the older firmware
version to confirm.
IMPORTANT!
Non-Controlled (NC) versions of RUGGEDCOM ROS can not be downgraded to Controlled firmware
versions. However, Controlled firmware versions can be downgraded to an NC firmware version.
CAUTION!
Do not downgrade the RUGGEDCOM ROS boot version.
1.
Disconnect the device from the network.
Upgrading Firmware
to determine which versions/updates are available or contact Siemens Customer
.
Device Management
Section 3.11, "Resetting the